Frequency Shift Imaging Using an Adiabatic SLR Self-Refocused Pulse for Positive-Contrast SPION Imaging at 7T
Purpose: Superparamagnetic iron oxide nanoparticles (SPION) are widely used as MRI contrast agents for cell tracking and molecular imaging. However, their detection using conventional T2/T2* weighted and susceptibility-weighted MRI relies on negative contrast (signal voids), which lacks specificity because similar hypointense signals can arise from other sources of magnetic susceptibility. This study introduces Frequency Shift Imaging (FSI), a positive-contrast technique based on an adiabatic Shinnar-Le Roux (SLR) self-refocused pulse that addresses the limited specificity of conventional SPION imaging. Methods: An adiabatic self-refocused RF pulse was designed using the SLR algorithm for frequency-selective positive-contrast imaging. The optimized pulse had a spectral bandwidth of 370 Hz, a peak RF amplitude of 13 μT, and a duration of 15 ms. FSI data were acquired on a 7T MRI scanner. Phantom experiments used agarose-embedded 30 nm cell-labeled SPION at 0%, 25%, 75%, and 100% concentrations (pure). In vivo validation was performed following intramuscular SPION injection into the hind limb of a mouse. FSI images were compared with conventional acquisitions. Results: Quantitative phantom analysis showed normalized FSI signal intensities of 25.02% and 75.16% for samples containing 25% and 75% labeled cells, respectively, demonstrating an approximately proportional relationship between FSI signal and labeled-cell concentration. In vivo, FSI generated localized hyperintense positive contrast at the SPION injection site, providing improved conspicuity compared with the corresponding negative-contrast signal void. Discussion and Conclusion: FSI enables frequency-selective positive-contrast SPION imaging at 7T with improved robustness to B1 variations and a shorter calculated minimum echo time compared with the corresponding separate pulse-pair configuration. The self-refocused design may also offer potential advantages in RF power deposition, although SAR reduction remains to be quantitatively evaluated.
Authors
- Judy Alper (ORCID: https://orcid.org/0000-0002-3422-4032)
- Priti Balchandani (ORCID: https://orcid.org/0000-0001-7709-5835)
- Akbar Alipour (ORCID: https://orcid.org/0000-0002-7981-6808)
- Abraham J. P. Teunissen (ORCID: https://orcid.org/0000-0002-0401-8262)
- Gaurav Verma (ORCID: https://orcid.org/0000-0002-7157-439X)
- Hadrien Dyvorne
- Zahi A. Fayad
- Madison Chiu
- Shams Rashid
Institutions
- Icahn School of Medicine at Mount Sinai (US)
Publication Details
- Journal
- Sensors
- Published
- 2026-11-19
- DOI
- https://doi.org/10.3390/s26227302
- Primary Topic
- Advanced MRI Techniques and Applications
- Type
- article
- Field-Weighted Citation Impact
- 0.00