On-Device ECG and Vital-Sign Prediction of 24-Hour Mortality and Unplanned ICU Admission in Emergency Department Patients: A Retrospective Evaluation of MEDI-AI

Background/Objectives: Smartphone-based analysis of electrocardiograms (ECGs) and vital signs may support risk assessment without an integrated electronic health record feed. We evaluated MEDI-AI for 24 h mortality and unplanned intensive care unit (ICU) admission, with secondary diagnostic and triage assessments. Methods: This single-center retrospective evaluation included 2000 encounters from 2025 after supplementary development on 3000 encounters from 2024, with patient-level separation. Stored probabilities were assessed for area under the receiver-operating-characteristic curve (AUROC), calibration, and threshold performance. Post hoc exploratory NEWS2 and paired comparisons were performed; accepted inputs were also analyzed separately. Results: There were 189 deaths and 378 ICU admissions. Fusion AUROCs were 0.9994 and 0.9982; NEWS2 AUROCs were 0.8801 and 0.8131. Fusion-minus-vital-only AUROC differences were −0.000039 (95% CI, −0.000450 to 0.000366) and 0.002114 (0.000632 to 0.003920). Fusion calibration slopes were 5.62 and 6.09. STEMI and ACS sensitivities were 90.9% (58.7–99.8%) and 92.3% (74.9–99.1%). Triage critical-class recall was 24.9%. Input rejection occurred in 48 encounters; median recorded latency was 1235 ms. These stored-score estimates do not measure end-to-end deployable performance. Conclusions: Near-ceiling stored-score discrimination did not establish reliable absolute risks or a clinically usable workflow. Incomplete predictor-timing and model-development records limit reproducibility and assessment of bias. The evaluated triage configuration is unsuitable for clinical deployment, and the diagnostic analyses do not validate rule-out use. Independent external and prospective validation are required.

Authors

Institutions

Publication Details

Journal
Diagnostics
Published
2026-09-28
DOI
https://doi.org/10.3390/diagnostics16193153
Primary Topic
Healthcare Technology and Patient Monitoring
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
article

On-Device ECG and Vital-Sign Prediction of 24-Hour Mortality and Unplanned ICU Admission in Emergency Department Patients: A Retrospective Evaluation of MEDI-AI

Hyuksool Kwon, Dongbum Suh, Jin Hee Lee, Hyunjin Kyung
Diagnostics
Healthcare Technology and Patient Monitoring
article

On-Device ECG and Vital-Sign Prediction of 24-Hour Mortality and Unplanned ICU Admission in Emergency Department Patients: A Retrospective Evaluation of MEDI-AI

Hyuksool Kwon, Dongbum Suh, Jin Hee Lee, Hyunjin Kyung
article en

Abstract

Background/Objectives: Smartphone-based analysis of electrocardiograms (ECGs) and vital signs may support risk assessment without an integrated electronic health record feed. We evaluated MEDI-AI for 24 h mortality and unplanned intensive care unit (ICU) admission, with secondary diagnostic and triage assessments. Methods: This single-center retrospective evaluation included 2000 encounters from 2025 after supplementary development on 3000 encounters from 2024, with patient-level separation. Stored probabilities were assessed for area under the receiver-operating-characteristic curve (AUROC), calibration, and threshold performance. Post hoc exploratory NEWS2 and paired comparisons were performed; accepted inputs were also analyzed separately. Results: There were 189 deaths and 378 ICU admissions. Fusion AUROCs were 0.9994 and 0.9982; NEWS2 AUROCs were 0.8801 and 0.8131. Fusion-minus-vital-only AUROC differences were −0.000039 (95% CI, −0.000450 to 0.000366) and 0.002114 (0.000632 to 0.003920). Fusion calibration slopes were 5.62 and 6.09. STEMI and ACS sensitivities were 90.9% (58.7–99.8%) and 92.3% (74.9–99.1%). Triage critical-class recall was 24.9%. Input rejection occurred in 48 encounters; median recorded latency was 1235 ms. These stored-score estimates do not measure end-to-end deployable performance. Conclusions: Near-ceiling stored-score discrimination did not establish reliable absolute risks or a clinically usable workflow. Incomplete predictor-timing and model-development records limit reproducibility and assessment of bias. The evaluated triage configuration is unsuitable for clinical deployment, and the diagnostic analyses do not validate rule-out use. Independent external and prospective validation are required.

DiagnosticsVol. 16(19)
Seoul National University Bundang Hospital (KR)
Gender equality
Openalex Percentile: Top 9%
Healthcare Technology and Patient Monitoring
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

On-Device ECG and Vital-Sign Prediction of 24-Hour Mortality and Unplanned ICU Admission in Emergency Department Patients: A Retrospective Evaluation of MEDI-AI — Hyuksool Kwon, Dongbum Suh, et al. · Diagnostics (2026) | TGRS Research Map | TGRS