Revisiting Artifact Suppression in Electrospray Ionization Deconvolution

Abstract Charge-state assignment is a critical step in many workflows for intact protein analysis by mass spectrometry. Computational deconvolution algorithms are increasingly used to automate data analysis, but conventional approaches can introduce artifacts. Here, we explore several approaches to removing artifacts by limiting the charge-state assignments for each data point. One approach removes satellite charge states surrounding the local maxima. Another removes harmonics at double the more probable charge assignment. The last two limit either the total number of allowed charge-state assignments or the minimum relative charge-state assignment probability for a given data point. These new features are as effective as the prior SoftMax artifact removal in UniDec, but they enable easier tuning by the user. Although the new set of features introduces additional complexity and an expanded number of parameters, these tools enable users to more precisely reduce artifacts in the deconvolution results.

Authors

Institutions

Publication Details

Journal
Journal of the American Society for Mass Spectrometry
Published
2026-11-14
DOI
https://doi.org/10.1021/jasms.6c00407
Primary Topic
Mass Spectrometry Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Revisiting Artifact Suppression in Electrospray Ionization Deconvolution

Michael Thomas Marty
1 links
Journal of the American Society for Mass Spectrometry
Mass Spectrometry Techniques and Applications
article

Revisiting Artifact Suppression in Electrospray Ionization Deconvolution

Michael Thomas Marty
article en

Abstract

Abstract Charge-state assignment is a critical step in many workflows for intact protein analysis by mass spectrometry. Computational deconvolution algorithms are increasingly used to automate data analysis, but conventional approaches can introduce artifacts. Here, we explore several approaches to removing artifacts by limiting the charge-state assignments for each data point. One approach removes satellite charge states surrounding the local maxima. Another removes harmonics at double the more probable charge assignment. The last two limit either the total number of allowed charge-state assignments or the minimum relative charge-state assignment probability for a given data point. These new features are as effective as the prior SoftMax artifact removal in UniDec, but they enable easier tuning by the user. Although the new set of features introduces additional complexity and an expanded number of parameters, these tools enable users to more precisely reduce artifacts in the deconvolution results.

Journal of the American Society for Mass Spectrometry
The University of Texas at Austin (US)
National Science Foundation, Amgen, Division of Chemistry
Mass Spectrometry Techniques and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon
Revisiting Artifact Suppression in Electrospray Ionization Deconvolution — Michael Thomas Marty · Journal of the American Society for Mass Spectrometry (2026) | TGRS Research Map | TGRS