Ability of the HALP Score to Predict Cardiac Implantable Electronic Device‐Related Complications

BACKGROUND: The hemoglobin, albumin, lymphocyte, and platelet score (HALP) is a recently defined score that indicates patients' inflammation and nutritional status. This score is associated with poor outcomes in cardiovascular diseases. We aimed to examine the relationship between the HALP score and complications related to cardiac implantable electronic devices (CIED) in patients undergoing CIED procedures. METHODS: Our study included 998 patients who underwent CIED implantation in our hospital between January 2019 and May 2022. Patients were divided into two groups according to the median HALP score. The low HALP score group consisted of patients with a HALP score < 40.63, and the high HALP score group consisted of patients with a HALP score ≥40.63. There were 499 patients in both groups. The endpoint of our study was cumulative events, including infection, pneumothorax, and hematoma secondary to CIED. RESULTS: The mean age of the population was 63.9 ± 13.8 years, and 61.5% (615) of the population were male patients. In the multivariate logistic regression analyses, hypertension (OR = 4.216, p < 0.001), biventricular ICD implantation (OR = 16.894, p < 0.001), and HALP score (OR = 0.973, p < 0.001) were independent predictors of cumulative event. In the ROC curve analysis, the HALP score cut-off value of 40.03 was 60.8% sensitive and 52.4% specific for cumulative events (AUC = 59.5%, p = 0.007). CONCLUSION: Our study observed that the HALP score was an independent predictor of cumulative complications related to CIED procedures. In light of this study, we think that the easily calculated HALP score may be useful in predicting complications in physicians performing CIED procedures.

Authors

Institutions

Publication Details

Journal
Pacing and Clinical Electrophysiology
Published
2026-09-25
DOI
https://doi.org/10.1111/pace.70441
Primary Topic
Inflammatory Biomarkers in Disease Prognosis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
article

Ability of the HALP Score to Predict Cardiac Implantable Electronic Device‐Related Complications

Serdar Söner, Gamze Yeter Arslan
Pacing and Clinical Electrophysiology
Inflammatory Biomarkers in Disease Prognosis
article

Ability of the HALP Score to Predict Cardiac Implantable Electronic Device‐Related Complications

Serdar Söner, Gamze Yeter Arslan
article en

Abstract

BACKGROUND: The hemoglobin, albumin, lymphocyte, and platelet score (HALP) is a recently defined score that indicates patients' inflammation and nutritional status. This score is associated with poor outcomes in cardiovascular diseases. We aimed to examine the relationship between the HALP score and complications related to cardiac implantable electronic devices (CIED) in patients undergoing CIED procedures. METHODS: Our study included 998 patients who underwent CIED implantation in our hospital between January 2019 and May 2022. Patients were divided into two groups according to the median HALP score. The low HALP score group consisted of patients with a HALP score < 40.63, and the high HALP score group consisted of patients with a HALP score ≥40.63. There were 499 patients in both groups. The endpoint of our study was cumulative events, including infection, pneumothorax, and hematoma secondary to CIED. RESULTS: The mean age of the population was 63.9 ± 13.8 years, and 61.5% (615) of the population were male patients. In the multivariate logistic regression analyses, hypertension (OR = 4.216, p < 0.001), biventricular ICD implantation (OR = 16.894, p < 0.001), and HALP score (OR = 0.973, p < 0.001) were independent predictors of cumulative event. In the ROC curve analysis, the HALP score cut-off value of 40.03 was 60.8% sensitive and 52.4% specific for cumulative events (AUC = 59.5%, p = 0.007). CONCLUSION: Our study observed that the HALP score was an independent predictor of cumulative complications related to CIED procedures. In light of this study, we think that the easily calculated HALP score may be useful in predicting complications in physicians performing CIED procedures.

Pacing and Clinical Electrophysiology
Antalya Eğitim ve Araştırma Hastanesi (TR), Sağlık Bilimleri Üniversitesi (TR), Diyarbakır Gazi Yaşargil Eğitim ve Araştırma Hastanesi (TR), Antalya IVF (TR)
Zero hunger
Openalex Percentile: Top 15%
Inflammatory Biomarkers in Disease Prognosis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Ability of the HALP Score to Predict Cardiac Implantable Electronic Device‐Related Complications — Serdar Söner, Gamze Yeter Arslan · Pacing and Clinical Electrophysiology (2026) | TGRS Research Map | TGRS