Modulating proteoform charge states and signal intensities in LC-MS using a nanoflow sheath liquid interface

To investigate intact proteins in biological samples, hyphenation of mass spectrometers (MS) with separation techniques like liquid chromatography (LC) or capillary zone electrophoresis (CZE) is crucial. While reversed-phase nanoLC is typically coupled directly (“sheathless”) to a mass spectrometer, for CZE-MS coupling, sheath liquid interfaces are typically used. Here, we coupled the reversed-phase nanoLC to an Orbitrap Fusion Lumos using a nanoflow sheath liquid interface (nanoCEasy-interface) and compared the results with the conventional (“sheathless”) coupling. We investigated the influence of emitter orifice diameter and the use of sheath liquid on proteoform ionization using constant LC flow independently of any high voltage as required for CZE separations. We found that a smaller emitter orifice is beneficial regarding proteoform intensity. Furthermore, the used sheath liquid also has a major effect on the resulting proteoform intensity, especially for emitters with a larger orifice and thus increased dilution of the column’s effluent with sheath liquid. Additionally, the sheath liquid influenced the charge state distributions of proteoforms, e.g., shifting the most abundant charge state of histone H4 from 15+ to 8+ upon addition of a 2-propanol:water (1:1, v/v) with 0.5% formic acid sheath liquid to the column effluent. This approach allows for easily reducing co-isolation of proteoforms by shifting their charge states to higher m/z and thus increasing the m/z difference between proteoforms with similar mass.

Authors

Institutions

Publication Details

Journal
Analytical and Bioanalytical Chemistry
Published
2026-09-25
DOI
https://doi.org/10.1007/s00216-026-06835-1
Primary Topic
Mass Spectrometry Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
article

Modulating proteoform charge states and signal intensities in LC-MS using a nanoflow sheath liquid interface

Philipp T. Kaulich, Christian Neusüß, Tobias Waldmann
Analytical and Bioanalytical Chemistry
Mass Spectrometry Techniques and Applications
article

Modulating proteoform charge states and signal intensities in LC-MS using a nanoflow sheath liquid interface

Philipp T. Kaulich, Christian Neusüß, Tobias Waldmann
article en

Abstract

To investigate intact proteins in biological samples, hyphenation of mass spectrometers (MS) with separation techniques like liquid chromatography (LC) or capillary zone electrophoresis (CZE) is crucial. While reversed-phase nanoLC is typically coupled directly (“sheathless”) to a mass spectrometer, for CZE-MS coupling, sheath liquid interfaces are typically used. Here, we coupled the reversed-phase nanoLC to an Orbitrap Fusion Lumos using a nanoflow sheath liquid interface (nanoCEasy-interface) and compared the results with the conventional (“sheathless”) coupling. We investigated the influence of emitter orifice diameter and the use of sheath liquid on proteoform ionization using constant LC flow independently of any high voltage as required for CZE separations. We found that a smaller emitter orifice is beneficial regarding proteoform intensity. Furthermore, the used sheath liquid also has a major effect on the resulting proteoform intensity, especially for emitters with a larger orifice and thus increased dilution of the column’s effluent with sheath liquid. Additionally, the sheath liquid influenced the charge state distributions of proteoforms, e.g., shifting the most abundant charge state of histone H4 from 15+ to 8+ upon addition of a 2-propanol:water (1:1, v/v) with 0.5% formic acid sheath liquid to the column effluent. This approach allows for easily reducing co-isolation of proteoforms by shifting their charge states to higher m/z and thus increasing the m/z difference between proteoforms with similar mass.

Analytical and Bioanalytical Chemistry
Christian-Albrechts-Universität zu Kiel (DE), Hochschule Aalen (DE)
Clean water and sanitation
Openalex Percentile: Top 23%
Mass Spectrometry Techniques and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.