Background/Objectives: Despite advances in point-of-care (POC) blood test development, the lack of a simple, low-cost approach to the separation of capillary blood to generate liquid plasma remains a barrier to POC measurement of many analytes. The battery-operated, internally balanced Labcorp TrueSpin® centrifuge offers a potential POC solution for blood collected into a BDMicrotainer®. We compared the quality of plasma generated by TrueSpin centrifugation versus conventional centrifugation. Methods: Venipuncture was performed on 10 volunteers. After collection of blood into Sarstedt Monovettes® (Lithium Heparin with gel (LiHep/Gel), EDTA), blood from the same tubing was collected into three Microtainers (LiHep/gel, LiHep without gel (LiHep), EDTA). Microtainer and Monovette samples received TrueSpin and conventional centrifugation, respectively. Hemolysis index and plasma amino acids (n = 24) were measured for all Monovette and Microtainer plasma samples. For 3 additional volunteers, capillary blood was collected from the arm into LiHep/Gel and EDTA Microtainers using the Labcorp Comfort DrawTM device with a gentleheel® lancet and centrifuged (TrueSpin) to generate plasma. Results: TrueSpin centrifugation took approximately 10 min; batteries supported 8–11 runs. Microtainer plasma H-indices (including blood from Comfort Draw) were ≤10. For all 24 amino acids combined, measurements for TrueSpin Microtainer samples had excellent Pearson’s correlation (r > 0.99) with paired conventional Monovette plasma. Conclusions: Plasma quality after TrueSpin centrifugation of Microtainer blood samples is comparable to plasma quality after conventional Monovette centrifugation, including for capillary blood collected using the Comfort Draw. The TrueSpin was reliable and easy to use. The TrueSpin centrifuge has potential future use for POC plasma separation.

Authors

Institutions

Publication Details

Journal
Diagnostics
Published
2026-09-24
DOI
https://doi.org/10.3390/diagnostics16193088
Primary Topic
Clinical Laboratory Practices and Quality Control
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
article

Toward the Use of Centrifugation for Point-of-Care Plasma Separation: Evaluation of a Compact Battery-Powered Centrifuge

Adam S. Ptolemy, Nira R. Pollock, Sami Rifai, Alexander L. Kolb et al.
Diagnostics
Clinical Laboratory Practices and Quality Control
article

Toward the Use of Centrifugation for Point-of-Care Plasma Separation: Evaluation of a Compact Battery-Powered Centrifuge

Adam S. Ptolemy, Nira R. Pollock, Sami Rifai, Alexander L. Kolb, Ayse Mehmke
article en

Abstract

Background/Objectives: Despite advances in point-of-care (POC) blood test development, the lack of a simple, low-cost approach to the separation of capillary blood to generate liquid plasma remains a barrier to POC measurement of many analytes. The battery-operated, internally balanced Labcorp TrueSpin® centrifuge offers a potential POC solution for blood collected into a BDMicrotainer®. We compared the quality of plasma generated by TrueSpin centrifugation versus conventional centrifugation. Methods: Venipuncture was performed on 10 volunteers. After collection of blood into Sarstedt Monovettes® (Lithium Heparin with gel (LiHep/Gel), EDTA), blood from the same tubing was collected into three Microtainers (LiHep/gel, LiHep without gel (LiHep), EDTA). Microtainer and Monovette samples received TrueSpin and conventional centrifugation, respectively. Hemolysis index and plasma amino acids (n = 24) were measured for all Monovette and Microtainer plasma samples. For 3 additional volunteers, capillary blood was collected from the arm into LiHep/Gel and EDTA Microtainers using the Labcorp Comfort DrawTM device with a gentleheel® lancet and centrifuged (TrueSpin) to generate plasma. Results: TrueSpin centrifugation took approximately 10 min; batteries supported 8–11 runs. Microtainer plasma H-indices (including blood from Comfort Draw) were ≤10. For all 24 amino acids combined, measurements for TrueSpin Microtainer samples had excellent Pearson’s correlation (r > 0.99) with paired conventional Monovette plasma. Conclusions: Plasma quality after TrueSpin centrifugation of Microtainer blood samples is comparable to plasma quality after conventional Monovette centrifugation, including for capillary blood collected using the Comfort Draw. The TrueSpin was reliable and easy to use. The TrueSpin centrifuge has potential future use for POC plasma separation.

DiagnosticsVol. 16(19)
Boston Children's Hospital (US)
Openalex Percentile: Top 11%
Clinical Laboratory Practices and Quality Control
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Toward the Use of Centrifugation for Point-of-Care Plasma Separation: Evaluation of a Compact Battery-Powered Centrifuge — Adam S. Ptolemy, Nira R. Pollock, et al. · Diagnostics (2026) | TGRS Research Map | TGRS