Multi-objective optimization of a Variable-displacement Voronoi Perforated Façade for office buildings

Dynamic façades can improve environmental responsiveness but often require complex sensing, control, and mechanical systems, whereas conventional double-skin perforated façades (DSPFs) are generally limited by fixed configurations. To address this gap, this study proposes a Variable-displacement Voronoi Perforated Façade (VDPF), consisting of three perforated layers that form multiple predefined configurations through relative interlayer displacement. Voronoi-based non-uniform perforation is incorporated through parametric modeling to regulate solar penetration and daylight distribution. A south-facing office unit in Qingdao is evaluated using Energy Use Intensity (EUI), Useful Daylight Illuminance (UDI 100-3000 ), and spatial Glare Autonomy (sGA). The simulation workflow is further examined through scaled experimental measurements of temperature and illuminance, and multi-objective optimization is subsequently conducted using non-dominated sorting, followed by a multi-criteria decision-making framework integrating scenario-based subjective weighting, CRITIC-based objective weighting, TOPSIS, and rank-sum aggregation. The selected compromise configuration reduces EUI by 5.03% while increasing UDI 100-3000 and sGA by 18.51% and 27.78%, respectively, compared with the baseline. Sensitivity analysis shows that L2 displacement has a greater overall influence than L3 displacement, particularly on energy use and glare protection. The effective perforation ratio also exhibits a clear performance trade-off, with the 15-30% range providing a comparatively balanced combination of energy efficiency, daylight availability, and visual comfort, while differences among Voronoi seed realizations remain relatively limited. These results demonstrate that predefined interlayer displacement combined with non-uniform perforation provides an effective framework for balancing multiple façade performance objectives without relying on continuous real-time actuation.

Authors

Institutions

Publication Details

Journal
Case Studies in Thermal Engineering
Published
2026-11-16
DOI
https://doi.org/10.1016/j.csite.2026.108728
Primary Topic
Building Energy and Comfort Optimization
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Multi-objective optimization of a Variable-displacement Voronoi Perforated Façade for office buildings

Qingsong Ma, Pengcheng Wang, Jiayi Guo, Xinyi Zhang et al.
2 links
Case Studies in Thermal Engineering
Building Energy and Comfort Optimization
article

Multi-objective optimization of a Variable-displacement Voronoi Perforated Façade for office buildings

Qingsong Ma, Pengcheng Wang, Jiayi Guo, Xinyi Zhang, Xinxin Wang
article en

Abstract

Dynamic façades can improve environmental responsiveness but often require complex sensing, control, and mechanical systems, whereas conventional double-skin perforated façades (DSPFs) are generally limited by fixed configurations. To address this gap, this study proposes a Variable-displacement Voronoi Perforated Façade (VDPF), consisting of three perforated layers that form multiple predefined configurations through relative interlayer displacement. Voronoi-based non-uniform perforation is incorporated through parametric modeling to regulate solar penetration and daylight distribution. A south-facing office unit in Qingdao is evaluated using Energy Use Intensity (EUI), Useful Daylight Illuminance (UDI 100-3000 ), and spatial Glare Autonomy (sGA). The simulation workflow is further examined through scaled experimental measurements of temperature and illuminance, and multi-objective optimization is subsequently conducted using non-dominated sorting, followed by a multi-criteria decision-making framework integrating scenario-based subjective weighting, CRITIC-based objective weighting, TOPSIS, and rank-sum aggregation. The selected compromise configuration reduces EUI by 5.03% while increasing UDI 100-3000 and sGA by 18.51% and 27.78%, respectively, compared with the baseline. Sensitivity analysis shows that L2 displacement has a greater overall influence than L3 displacement, particularly on energy use and glare protection. The effective perforation ratio also exhibits a clear performance trade-off, with the 15-30% range providing a comparatively balanced combination of energy efficiency, daylight availability, and visual comfort, while differences among Voronoi seed realizations remain relatively limited. These results demonstrate that predefined interlayer displacement combined with non-uniform perforation provides an effective framework for balancing multiple façade performance objectives without relying on continuous real-time actuation.

Case Studies in Thermal EngineeringVol. 88
Qingdao University of Technology (CN)
National Natural Science Foundation of China
Sustainable cities and communities, Affordable and clean energy
Building Energy and Comfort Optimization
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon