Comparative assessment of CBCT and digital radiography in quantifying periapical pathology (in vitro study)

Abstract Objective To compare the diagnostic accuracy of phosphor plate-based digital periapical radiography (DPR) and CBCT in quantifying periapical lesions compared to the reference standard. Materials and methods This in vitro study included 45 premolar teeth with simulated periapical lesions created in dry human mandibles. The lesions were categorized into three groups according to size. All specimens were imaged using DPR with the paralleling technique (70–80kVp, 8mA, 0.16–0.32s). CBCT imaging was performed using the i-CAT Next Generation system (120kVp, 5mA, 26.9s, 0.25mm voxel size). Lesion lengths obtained from both imaging modalities were compared with the actual lesion dimensions (reference standard) to assess diagnostic accuracy. Intra-examiner reliability was evaluated. Results Group I's mean lesion length was 1.2mm, Group II's was 1.5mm, and Group III's was 1.8mm. In comparison to the reference standard, PR frequently overestimated the length of lesions. CBCT, on the other hand, showed better accuracy, and greater consistency. A propensity to underestimate minor lesions was indicated by the mean CBCT measurement of 1.07 ± 0.20mm at 1.2 mm group ( p = 0.020). At 1.5mm, CBCT assessed 1.72 ± 0.19mm ( p = 0.001) while no significant difference observed at 1.8mm ( p = 0.065). Conclusions While CBCT is more reliable than PR, its precision is influenced by lesion size, performing most accurately with larger periapical pathologies. Clinical relevance Periapical radiography should be interpreted with caution when assessing periapical pathology, as it may lead to overestimation of lesion size. In contrast, CBCT can be regarded as the reference standard, especially for lesions larger than 1.5mm.

Authors

Publication Details

Journal
BMC Oral Health
Published
2026-09-25
DOI
https://doi.org/10.1186/s12903-026-09816-z
Primary Topic
Dental Radiography and Imaging
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
article

Comparative assessment of CBCT and digital radiography in quantifying periapical pathology (in vitro study)

Esraa A. Elnadoury, Hassan Mohamed Abouelkheir, Abdelmonem Dahrous
BMC Oral Health
Dental Radiography and Imaging
article

Comparative assessment of CBCT and digital radiography in quantifying periapical pathology (in vitro study)

Esraa A. Elnadoury, Hassan Mohamed Abouelkheir, Abdelmonem Dahrous
article en

Abstract

Abstract Objective To compare the diagnostic accuracy of phosphor plate-based digital periapical radiography (DPR) and CBCT in quantifying periapical lesions compared to the reference standard. Materials and methods This in vitro study included 45 premolar teeth with simulated periapical lesions created in dry human mandibles. The lesions were categorized into three groups according to size. All specimens were imaged using DPR with the paralleling technique (70–80kVp, 8mA, 0.16–0.32s). CBCT imaging was performed using the i-CAT Next Generation system (120kVp, 5mA, 26.9s, 0.25mm voxel size). Lesion lengths obtained from both imaging modalities were compared with the actual lesion dimensions (reference standard) to assess diagnostic accuracy. Intra-examiner reliability was evaluated. Results Group I's mean lesion length was 1.2mm, Group II's was 1.5mm, and Group III's was 1.8mm. In comparison to the reference standard, PR frequently overestimated the length of lesions. CBCT, on the other hand, showed better accuracy, and greater consistency. A propensity to underestimate minor lesions was indicated by the mean CBCT measurement of 1.07 ± 0.20mm at 1.2 mm group ( p = 0.020). At 1.5mm, CBCT assessed 1.72 ± 0.19mm ( p = 0.001) while no significant difference observed at 1.8mm ( p = 0.065). Conclusions While CBCT is more reliable than PR, its precision is influenced by lesion size, performing most accurately with larger periapical pathologies. Clinical relevance Periapical radiography should be interpreted with caution when assessing periapical pathology, as it may lead to overestimation of lesion size. In contrast, CBCT can be regarded as the reference standard, especially for lesions larger than 1.5mm.

BMC Oral HealthVol. 26(1)
Openalex Percentile: Top 9%
Dental Radiography and Imaging
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.