Computational fluid dynamics assessment of hemodynamic effects of catheter navigation during transcatheter aortic valve implantation

Background: Transcatheter aortic valve implantation (TAVI) is a widely adopted, minimally invasive alternative to surgical aortic valve replacement. Despite its clinical success, TAVI can induce hemodynamic complications, which can be investigated using computational fluid dynamics (CFD). In this study, CFD was applied to evaluate the hemodynamic impact of catheter insertion during the TAVI procedure. Methods: CFD simulations were conducted in SimVascular to assess blood flow alterations at different stages of catheter insertion, from the iliac access to the ascending aorta, focusing on four critical phases of catheter advancement. Hemodynamic parameters were systematically analyzed across all simulated models. Results: Catheter insertion induced a pronounced local pressure drop and elevated wall shear stress (WSS) at the access-side iliac artery. Outlet flow analysis showed redistribution across branches, with reduced flow on the access side and compensatory increases in the contralateral femoral artery and the other branches. Oscillatory shear index (OSI) and turbulent kinetic energy (TKE) were reduced at the access site, whereas higher OSI and TKE were observed in the contralateral iliac artery. Local hemodynamics and WSS near the catheter tip were found to be sensitive to the catheter’s longitudinal position. Conclusion: This proof-of-concept study demonstrates that CFD can effectively capture catheter-induced hemodynamic disturbances during TAVI delivery, providing a foundation for patient-specific risk assessment and procedural optimization.

Authors

Institutions

Publication Details

Journal
The International Journal of Artificial Organs
Published
2026-09-24
DOI
https://doi.org/10.1177/03913988261486186
Primary Topic
Cardiac Valve Diseases and Treatments
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
article

Computational fluid dynamics assessment of hemodynamic effects of catheter navigation during transcatheter aortic valve implantation

Francesco Carlo Massa, Ettore Lanzarone, Luca Soliveri, Alessandro Mazzocchi et al.
The International Journal of Artificial Organs
Cardiac Valve Diseases and Treatments
article

Computational fluid dynamics assessment of hemodynamic effects of catheter navigation during transcatheter aortic valve implantation

Francesco Carlo Massa, Ettore Lanzarone, Luca Soliveri, Alessandro Mazzocchi, Matteo Grassi, Nicola Vezzoli
article en

Abstract

Background: Transcatheter aortic valve implantation (TAVI) is a widely adopted, minimally invasive alternative to surgical aortic valve replacement. Despite its clinical success, TAVI can induce hemodynamic complications, which can be investigated using computational fluid dynamics (CFD). In this study, CFD was applied to evaluate the hemodynamic impact of catheter insertion during the TAVI procedure. Methods: CFD simulations were conducted in SimVascular to assess blood flow alterations at different stages of catheter insertion, from the iliac access to the ascending aorta, focusing on four critical phases of catheter advancement. Hemodynamic parameters were systematically analyzed across all simulated models. Results: Catheter insertion induced a pronounced local pressure drop and elevated wall shear stress (WSS) at the access-side iliac artery. Outlet flow analysis showed redistribution across branches, with reduced flow on the access side and compensatory increases in the contralateral femoral artery and the other branches. Oscillatory shear index (OSI) and turbulent kinetic energy (TKE) were reduced at the access site, whereas higher OSI and TKE were observed in the contralateral iliac artery. Local hemodynamics and WSS near the catheter tip were found to be sensitive to the catheter’s longitudinal position. Conclusion: This proof-of-concept study demonstrates that CFD can effectively capture catheter-induced hemodynamic disturbances during TAVI delivery, providing a foundation for patient-specific risk assessment and procedural optimization.

The International Journal of Artificial Organs
University of Bergamo (IT)
Good health and well-being
Openalex Percentile: Top 11%
Cardiac Valve Diseases and Treatments
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Computational fluid dynamics assessment of hemodynamic effects of catheter navigation during transcatheter aortic valve implantation — Francesco Carlo Massa, Ettore Lanzarone, et al. · The International Journal of Artificial Organs (2026) | TGRS Research Map | TGRS