A Dexamethasone-Loaded Compact Intraocular Lens for Cataract Surgery: Validation in an in Vivo Pilot Study

Abstract Intraocular lens (IOL) implantation is widely performed, but poor adherence to traditional eye drop therapy and low drug bioavailability increase the risk of postoperative inflammation and infection. Although many drug delivery strategies have been proposed, in vivo evidence is limited, and scalability remains a key challenge for clinical use. In this study, we introduce a compact dexamethasone (DXM)-loaded IOL fabricated through a simple, low-cost, one-step process by embedding DXM within a biocompatible polydimethylsiloxane (PDMS)-based polymer matrix. The DXM-loaded IOL was evaluated in in vitro assays and in seven New Zealand–California White rabbits undergoing cataract surgery, with the DXM-loaded IOL implanted in the right eye and a nonloaded IOL used as a control in the left eye. Aqueous humor samples were collected at different time points to assess prostaglandin E2 (PGE2) levels as an inflammatory biomarker, as well as DXM release. Drug release ranged from 31% to 99% (2.1–8.5 μg), and PGE2 levels were lower in eyes implanted with the DXM-loaded IOL than in control eyes, indicating reduced inflammation. In conclusion, we present a preclinical validated prototype of a dual-function IOL that maintains visual performance and reduces postoperative inflammation.

Authors

Institutions

Publication Details

Journal
ACS Applied Bio Materials
Published
2026-09-24
DOI
https://doi.org/10.1021/acsabm.6c00877
Primary Topic
Intraocular Surgery and Lenses
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
article

A Dexamethasone-Loaded Compact Intraocular Lens for Cataract Surgery: Validation in an in Vivo Pilot Study

N. Jornet‐Martínez, Mariola Penadés Fons, María José Roig Revert, Cristina Peris‐Martínez et al.
ACS Applied Bio Materials
Intraocular Surgery and Lenses
article

A Dexamethasone-Loaded Compact Intraocular Lens for Cataract Surgery: Validation in an in Vivo Pilot Study

N. Jornet‐Martínez, Mariola Penadés Fons, María José Roig Revert, Cristina Peris‐Martínez, Aloma Mayordomo Febrer, María José Luque Cobija, Pilar Campíns-Falcó, Rocío Navarro Utiel, Cristina Martínez Gil, Mª Carmen García Domene, Cristina Artigas Felipe, José María Artigas Verde, María López Murcia, Lucía Benavente Cobo
article en

Abstract

Abstract Intraocular lens (IOL) implantation is widely performed, but poor adherence to traditional eye drop therapy and low drug bioavailability increase the risk of postoperative inflammation and infection. Although many drug delivery strategies have been proposed, in vivo evidence is limited, and scalability remains a key challenge for clinical use. In this study, we introduce a compact dexamethasone (DXM)-loaded IOL fabricated through a simple, low-cost, one-step process by embedding DXM within a biocompatible polydimethylsiloxane (PDMS)-based polymer matrix. The DXM-loaded IOL was evaluated in in vitro assays and in seven New Zealand–California White rabbits undergoing cataract surgery, with the DXM-loaded IOL implanted in the right eye and a nonloaded IOL used as a control in the left eye. Aqueous humor samples were collected at different time points to assess prostaglandin E2 (PGE2) levels as an inflammatory biomarker, as well as DXM release. Drug release ranged from 31% to 99% (2.1–8.5 μg), and PGE2 levels were lower in eyes implanted with the DXM-loaded IOL than in control eyes, indicating reduced inflammation. In conclusion, we present a preclinical validated prototype of a dual-function IOL that maintains visual performance and reduces postoperative inflammation.

ACS Applied Bio Materials
Universitat de València (ES), Universidad Cardenal Herrera CEU (ES), Fundación para el Fomento de la Investigación Sanitaria y Biomédica de la Comunitat Valenciana (ES)
Good health and well-being
Openalex Percentile: Top 8%
Intraocular Surgery and Lenses
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.