CT EVALUATION OF CEMENTLESS GLENOID PROSTHESIS OSSEOINTEGRATION AND STABILITY IN TOTAL SHOULDER ARTHROPLASTY

In total shoulder arthroplasty a significant measure of long-term survivorship of the implant is rooted in the osseointegration of the glenoid component. The Mathys Affinis short vitamys implant brings similar properties seen in the RM pressfit acetabular cup to the shoulder containing a monobloc porous coated construction with osseointegrative properties. Using Computerised Tomography in this prospective cohort study, at 12 months we evaluated peri-peg osteolysis, independent peg osseointegration and migration of the glenoid component. As these are normally assessed on plane radiographs, we developed the Computed Tomography Fixation Integrity Score (CT-FIS) as an evaluation framework defining 4 grades of stability: stable fixation (0), “At risk / close review” (1), “Radiographically loose” (2) and grossly unstable (3). These grades are formed using revision arthroplasty definitions from CT based measurements of lucency incorporating Lazarus grading. Of 29 patients (mean age 67); 17 right, 13 left (1 with bilateral replacements), 20 were available for analysis. At one year, 85% of patients (17) demonstrated Grade 0 and 15% (3) Grade 1 using CT-FIS. No implants were radiographically loose. One patient scan showed osteolysis with cortical breach, but all showed at least partial osseointegration at superior and/or inferior pegs. No component migration was observed. This implant demonstrates early reliable osseointegration and low rates of lucency. The use of CT allows for volumetric assessment of implant success and development of our grading system will allow for quantifiable longitudinal analysis previously limited to two-dimensional radiographs.

Authors

Institutions

Publication Details

Journal
Orthopaedic Proceedings
Published
2026-09-24
DOI
https://doi.org/10.1302/1358-992x.2026.7.008
Primary Topic
Shoulder Injury and Treatment
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
article

CT EVALUATION OF CEMENTLESS GLENOID PROSTHESIS OSSEOINTEGRATION AND STABILITY IN TOTAL SHOULDER ARTHROPLASTY

D.A. Cairns, D. Goyal, K. Kumar, K. Kapur
Orthopaedic Proceedings
Shoulder Injury and Treatment
article

CT EVALUATION OF CEMENTLESS GLENOID PROSTHESIS OSSEOINTEGRATION AND STABILITY IN TOTAL SHOULDER ARTHROPLASTY

D.A. Cairns, D. Goyal, K. Kumar, K. Kapur
article en

Abstract

In total shoulder arthroplasty a significant measure of long-term survivorship of the implant is rooted in the osseointegration of the glenoid component. The Mathys Affinis short vitamys implant brings similar properties seen in the RM pressfit acetabular cup to the shoulder containing a monobloc porous coated construction with osseointegrative properties. Using Computerised Tomography in this prospective cohort study, at 12 months we evaluated peri-peg osteolysis, independent peg osseointegration and migration of the glenoid component. As these are normally assessed on plane radiographs, we developed the Computed Tomography Fixation Integrity Score (CT-FIS) as an evaluation framework defining 4 grades of stability: stable fixation (0), “At risk / close review” (1), “Radiographically loose” (2) and grossly unstable (3). These grades are formed using revision arthroplasty definitions from CT based measurements of lucency incorporating Lazarus grading. Of 29 patients (mean age 67); 17 right, 13 left (1 with bilateral replacements), 20 were available for analysis. At one year, 85% of patients (17) demonstrated Grade 0 and 15% (3) Grade 1 using CT-FIS. No implants were radiographically loose. One patient scan showed osteolysis with cortical breach, but all showed at least partial osseointegration at superior and/or inferior pegs. No component migration was observed. This implant demonstrates early reliable osseointegration and low rates of lucency. The use of CT allows for volumetric assessment of implant success and development of our grading system will allow for quantifiable longitudinal analysis previously limited to two-dimensional radiographs.

Orthopaedic ProceedingsVol. 108-B(SUPP_7)
Woodend Hospital (GB)
Openalex Percentile: Top 8%
Shoulder Injury and Treatment
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

CT EVALUATION OF CEMENTLESS GLENOID PROSTHESIS OSSEOINTEGRATION AND STABILITY IN TOTAL SHOULDER ARTHROPLASTY — D.A. Cairns, D. Goyal, et al. · Orthopaedic Proceedings (2026) | TGRS Research Map | TGRS