DCD-VMUNet: A Dynamic Multi-Scale and Geometry-Aware Network for Coronary Vessel and Stenosis Segmentation in X-Ray Angiography

Accurate segmentation of coronary vessels and stenotic regions in X-ray coronary angiography remains challenging because of low vessel-to-background contrast, vessel overlap, thin branches, and the small, ambiguous appearance of stenotic lesions. In this study, we propose DCD-VMUNet, a structure-aware framework for automated coronary vessel and stenosis segmentation. Built on VM-UNet, the model incorporates a dynamic multi-scale kernel module, a centerline head, and a direction head. The dynamic module adaptively integrates fine boundary details with broader contextual cues, while the auxiliary heads introduce geometric supervision to enhance structural continuity and orientation awareness. DCD-VMUNet was independently trained and evaluated for binary vessel and stenosis segmentation on the ARCADE dataset. It was compared with YOLOv11-X, DeepLab v3+, UNet, UNet++, TransUNet, MALUNet, and VM-UNet using pixel-wise metrics and, for vessel segmentation, the centerline-aware clDice metric. For vessel segmentation, DCD-VMUNet achieved the best performance, with IoU, precision, recall, and F1-score of 0.6838, 0.8418, 0.7846, and 0.8122. For stenosis segmentation, it also ranked first across all metrics, reaching 0.4042, 0.5826, 0.5688, and 0.5757, respectively. Ablation studies confirmed the complementary effects of multi-scale feature extraction and geometric supervision. Additional evaluation on the independent ICA dataset further supported the vessel segmentation performance of DCD-VMUNet beyond the ARCADE benchmark. These results indicate that DCD-VMUNet improves coronary vessel delineation and pixel-level stenosis localization, supporting automated coronary angiographic assessment.

Authors

Institutions

Publication Details

Journal
Bioengineering
Published
2026-09-24
DOI
https://doi.org/10.3390/bioengineering13101111
Primary Topic
Retinal Imaging and Analysis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
article

DCD-VMUNet: A Dynamic Multi-Scale and Geometry-Aware Network for Coronary Vessel and Stenosis Segmentation in X-Ray Angiography

Xiangyang Ma, Yan Quan, Huaizhi Yue, Kun Liu
Bioengineering
Retinal Imaging and Analysis
article

DCD-VMUNet: A Dynamic Multi-Scale and Geometry-Aware Network for Coronary Vessel and Stenosis Segmentation in X-Ray Angiography

Xiangyang Ma, Yan Quan, Huaizhi Yue, Kun Liu
article en

Abstract

Accurate segmentation of coronary vessels and stenotic regions in X-ray coronary angiography remains challenging because of low vessel-to-background contrast, vessel overlap, thin branches, and the small, ambiguous appearance of stenotic lesions. In this study, we propose DCD-VMUNet, a structure-aware framework for automated coronary vessel and stenosis segmentation. Built on VM-UNet, the model incorporates a dynamic multi-scale kernel module, a centerline head, and a direction head. The dynamic module adaptively integrates fine boundary details with broader contextual cues, while the auxiliary heads introduce geometric supervision to enhance structural continuity and orientation awareness. DCD-VMUNet was independently trained and evaluated for binary vessel and stenosis segmentation on the ARCADE dataset. It was compared with YOLOv11-X, DeepLab v3+, UNet, UNet++, TransUNet, MALUNet, and VM-UNet using pixel-wise metrics and, for vessel segmentation, the centerline-aware clDice metric. For vessel segmentation, DCD-VMUNet achieved the best performance, with IoU, precision, recall, and F1-score of 0.6838, 0.8418, 0.7846, and 0.8122. For stenosis segmentation, it also ranked first across all metrics, reaching 0.4042, 0.5826, 0.5688, and 0.5757, respectively. Ablation studies confirmed the complementary effects of multi-scale feature extraction and geometric supervision. Additional evaluation on the independent ICA dataset further supported the vessel segmentation performance of DCD-VMUNet beyond the ARCADE benchmark. These results indicate that DCD-VMUNet improves coronary vessel delineation and pixel-level stenosis localization, supporting automated coronary angiographic assessment.

BioengineeringVol. 13(10)
Union Hospital (HK), Chang'an University (CN), Huazhong University of Science and Technology (CN)
Openalex Percentile: Top 12%
Retinal Imaging and Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

DCD-VMUNet: A Dynamic Multi-Scale and Geometry-Aware Network for Coronary Vessel and Stenosis Segmentation in X-Ray Angiography — Xiangyang Ma, Yan Quan, et al. · Bioengineering (2026) | TGRS Research Map | TGRS