Spectral versus co-spectral correction of eddy-covariance fluxes: a multi-site assessment across the ICOS network

Accurate correction of high-frequency attenuation remains a critical challenge in eddy-covariance measurements of turbulent gas fluxes. Experimental correction approaches based on either power spectra or co-spectra are widely used, yet their relative behaviour and implications for flux estimates have not been systematically assessed across sites and atmospheric conditions. This study presents a multi-site comparison of these two approaches using one year of CO 2 and H 2 O flux data from 38 ecosystem stations of the Integrated Carbon Observation System (ICOS) equipped with a standardized enclosed-path gas analyser setup. To support reproducibility and facilitate future methodological intercomparisons, we additionally provide an open-source and configurable software tool implementing both correction approaches. Overall, the ICOS setup exhibited limited high-frequency attenuation, with correction factors generally below 1.2 for CO 2 and occasionally approaching 2 for H 2 O under humid conditions. For CO 2 , differences between methods remained small after standard turbulence filtering, with cumulative flux differences typically below 2 %. In contrast, H 2 O corrections showed larger discrepancies, frequently reaching 5 %–10 % on cumulative fluxes. The largest differences occurred under stable atmospheric conditions, at low measurement heights, and under strong attenuation. Results indicate that CO 2 attenuation is dominated by sensor-separation effects, whereas H 2 O attenuation is primarily controlled by adsorption–desorption processes within the sampling system. The comparison highlights methodological limitations of both approaches. Both methods rely on assumptions regarding spectral similarity, but departures from these assumptions were found to affect gas spectra much more strongly than co-spectra, particularly for H 2 O under humid conditions. In addition, spectral corrections were frequently affected by high-frequency noise and required dedicated denoising procedures, while sensor-separation effects had to be introduced through analytical formulations. Overall, the co-spectral approach provided more robust and physically consistent results across sites and atmospheric conditions. A comparison with fluxes produced by the ICOS Ecosystem Thematic Centre revealed systematic differences that were often larger than those observed between the spectral and co-spectral approaches themselves, especially for H 2 O. These results demonstrate the effectiveness of setup standardisation across the ICOS network while identifying high-frequency attenuation correction as a remaining source of uncertainty. They also highlight the need for a broader reassessment of this processing step within the ICOS flux-processing pipeline.

Authors

Institutions

Publication Details

Journal
Atmospheric measurement techniques
Published
2026-09-24
DOI
https://doi.org/10.5194/amt-19-6037-2026
Primary Topic
Atmospheric and Environmental Gas Dynamics
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
article

Spectral versus co-spectral correction of eddy-covariance fluxes: a multi-site assessment across the ICOS network

Bernard Heinesch, Gerardo Fratini, Giacomo Nicolini, Simone Sabbatini et al.
Atmospheric measurement techniques
Atmospheric and Environmental Gas Dynamics
article

Spectral versus co-spectral correction of eddy-covariance fluxes: a multi-site assessment across the ICOS network

Bernard Heinesch, Gerardo Fratini, Giacomo Nicolini, Simone Sabbatini, Dario Papale, Ariane Faurès
article en

Abstract

Accurate correction of high-frequency attenuation remains a critical challenge in eddy-covariance measurements of turbulent gas fluxes. Experimental correction approaches based on either power spectra or co-spectra are widely used, yet their relative behaviour and implications for flux estimates have not been systematically assessed across sites and atmospheric conditions. This study presents a multi-site comparison of these two approaches using one year of CO 2 and H 2 O flux data from 38 ecosystem stations of the Integrated Carbon Observation System (ICOS) equipped with a standardized enclosed-path gas analyser setup. To support reproducibility and facilitate future methodological intercomparisons, we additionally provide an open-source and configurable software tool implementing both correction approaches. Overall, the ICOS setup exhibited limited high-frequency attenuation, with correction factors generally below 1.2 for CO 2 and occasionally approaching 2 for H 2 O under humid conditions. For CO 2 , differences between methods remained small after standard turbulence filtering, with cumulative flux differences typically below 2 %. In contrast, H 2 O corrections showed larger discrepancies, frequently reaching 5 %–10 % on cumulative fluxes. The largest differences occurred under stable atmospheric conditions, at low measurement heights, and under strong attenuation. Results indicate that CO 2 attenuation is dominated by sensor-separation effects, whereas H 2 O attenuation is primarily controlled by adsorption–desorption processes within the sampling system. The comparison highlights methodological limitations of both approaches. Both methods rely on assumptions regarding spectral similarity, but departures from these assumptions were found to affect gas spectra much more strongly than co-spectra, particularly for H 2 O under humid conditions. In addition, spectral corrections were frequently affected by high-frequency noise and required dedicated denoising procedures, while sensor-separation effects had to be introduced through analytical formulations. Overall, the co-spectral approach provided more robust and physically consistent results across sites and atmospheric conditions. A comparison with fluxes produced by the ICOS Ecosystem Thematic Centre revealed systematic differences that were often larger than those observed between the spectral and co-spectral approaches themselves, especially for H 2 O. These results demonstrate the effectiveness of setup standardisation across the ICOS network while identifying high-frequency attenuation correction as a remaining source of uncertainty. They also highlight the need for a broader reassessment of this processing step within the ICOS flux-processing pipeline.

Atmospheric measurement techniquesVol. 19(18)
Università degli Studi della Tuscia (IT), University of Liège (BE), Gembloux Agro-Bio Tech (BE), CMCC Foundation - Euro-Mediterranean Center on Climate Change (IT)
Openalex Percentile: Top 14%
Atmospheric and Environmental Gas Dynamics
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.