Glutamate-binding protein from Corynebacterium glutamicum as fluorescence probe for glutamate detection in artificial cerebrospinal fluid

L-Glutamate (L-Glu) is the primary excitatory neurotransmitter in the mammalian central nervous system. In neurobiology, monitoring L-Glu accumulation is critical to track the neurodegeneration process, since excessive extracellular levels are caused by acute events like stroke, brain injuries, or malignant tumors. Conventional analytical methods are widely used to quantify L-Glu. Recently, alternative approaches based on biosensors have been developed for monitoring L-Glu in biological systems. In this work, we explored the use of the glutamate-binding protein (GluB), isolated from Corynebacterium glutamicum , as a specific probe to design a fluorescence biosensor for L-Glu detection. For this purpose, one of the three cysteine residues of GluB was labeled with the environment-sensitive fluorescence dye acrylodan. The stability of the labeled protein was assessed through thermal stability experiments. The binding of L-Glu to the GluB-acrylodan was investigated by steady-state and time-resolved fluorescence measurements. The results indicate the capability of the biosensor to effectively intercept the concentration values of L-Glu that are characteristic of acute clinical emergencies and tumor microenvironments before they can reach extreme neurotoxic levels. To explore the clinical potential application of the assay, GluB-acrylodan was tested through time-resolved fluorescence measurements in artificial cerebrospinal fluid (aCSF). The results showed a LoD of 19.70 µM, a threshold value that is compatible with the pathological concentrations of L-Glu. The results suggest that GluB-acrylodan could represent a potential tool for future applications in neurobiological research and cellular excitotoxic events.

Authors

Institutions

Publication Details

Journal
Scientific Reports
Published
2026-11-13
DOI
https://doi.org/10.1038/s41598-026-80347-x
Primary Topic
Advanced Fluorescence Microscopy Techniques
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Glutamate-binding protein from Corynebacterium glutamicum as fluorescence probe for glutamate detection in artificial cerebrospinal fluid

Antonio Varriale, Maria Staiano, Giovanni Ferrara, Sabato D’Auria et al.
2 links
Scientific Reports
Advanced Fluorescence Microscopy Techniques
article

Glutamate-binding protein from Corynebacterium glutamicum as fluorescence probe for glutamate detection in artificial cerebrospinal fluid

Antonio Varriale, Maria Staiano, Giovanni Ferrara, Sabato D’Auria, Ivana Milosevic, Vasa Radonic
article en

Abstract

L-Glutamate (L-Glu) is the primary excitatory neurotransmitter in the mammalian central nervous system. In neurobiology, monitoring L-Glu accumulation is critical to track the neurodegeneration process, since excessive extracellular levels are caused by acute events like stroke, brain injuries, or malignant tumors. Conventional analytical methods are widely used to quantify L-Glu. Recently, alternative approaches based on biosensors have been developed for monitoring L-Glu in biological systems. In this work, we explored the use of the glutamate-binding protein (GluB), isolated from Corynebacterium glutamicum , as a specific probe to design a fluorescence biosensor for L-Glu detection. For this purpose, one of the three cysteine residues of GluB was labeled with the environment-sensitive fluorescence dye acrylodan. The stability of the labeled protein was assessed through thermal stability experiments. The binding of L-Glu to the GluB-acrylodan was investigated by steady-state and time-resolved fluorescence measurements. The results indicate the capability of the biosensor to effectively intercept the concentration values of L-Glu that are characteristic of acute clinical emergencies and tumor microenvironments before they can reach extreme neurotoxic levels. To explore the clinical potential application of the assay, GluB-acrylodan was tested through time-resolved fluorescence measurements in artificial cerebrospinal fluid (aCSF). The results showed a LoD of 19.70 µM, a threshold value that is compatible with the pathological concentrations of L-Glu. The results suggest that GluB-acrylodan could represent a potential tool for future applications in neurobiological research and cellular excitotoxic events.

Scientific Reports
University of Novi Sad (RS), Institute of Food Science (IT), BioSense Institute (RS), National Research Council (IT)
European Commission, HORIZON EUROPE Framework Programme
Good health and well-being
Advanced Fluorescence Microscopy Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon