Epicardial Use of Medtronic 3830 Lead in Pediatric Cardiac Resynchronization Therapy with Elevated Thresholds

ABSTRACT Background Epicardial pacing is standard in children, but conventional leads often fail due to high thresholds, fractures, or poor sensing after multiple surgeries. Case A 10‐year‐old with restrictive cardiomyopathy and prior mitral valve replacement presented with loss of capture from fractured epicardial leads. Redo sternotomy attempts with conventional leads produced thresholds up to 8.0 V. A Medtronic SelectSecure 3830 lead was implanted epicardially, achieving improved thresholds (2.7 V → 1.1 V) and stable cardiac resynchronization therapy (CRT) pacemaker function. At 2 months, thresholds and impedances remained low and stable. Conclusion Epicardial Medtronic SelectSecure 3830 lead implantation may be a feasible alternative in complex pediatric redo cases.

Authors

Institutions

Publication Details

Journal
Pacing and Clinical Electrophysiology
Published
2026-09-21
DOI
https://doi.org/10.1111/pace.70349
Primary Topic
Cardiac pacing and defibrillation studies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
article

Epicardial Use of Medtronic 3830 Lead in Pediatric Cardiac Resynchronization Therapy with Elevated Thresholds

Volkan Tuzcu, Hüsnü Fırat Altın, Qusi Shaban, Olivier Ghez et al.
Pacing and Clinical Electrophysiology
Cardiac pacing and defibrillation studies
article

Epicardial Use of Medtronic 3830 Lead in Pediatric Cardiac Resynchronization Therapy with Elevated Thresholds

Volkan Tuzcu, Hüsnü Fırat Altın, Qusi Shaban, Olivier Ghez, Shadab Wani, Ahmed Reyaz Lone
article en

Abstract

ABSTRACT Background Epicardial pacing is standard in children, but conventional leads often fail due to high thresholds, fractures, or poor sensing after multiple surgeries. Case A 10‐year‐old with restrictive cardiomyopathy and prior mitral valve replacement presented with loss of capture from fractured epicardial leads. Redo sternotomy attempts with conventional leads produced thresholds up to 8.0 V. A Medtronic SelectSecure 3830 lead was implanted epicardially, achieving improved thresholds (2.7 V → 1.1 V) and stable cardiac resynchronization therapy (CRT) pacemaker function. At 2 months, thresholds and impedances remained low and stable. Conclusion Epicardial Medtronic SelectSecure 3830 lead implantation may be a feasible alternative in complex pediatric redo cases.

Pacing and Clinical Electrophysiology
Qatar Airways (Qatar) (QA)
No poverty
Openalex Percentile: Top 10%
Cardiac pacing and defibrillation studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Epicardial Use of Medtronic 3830 Lead in Pediatric Cardiac Resynchronization Therapy with Elevated Thresholds — Volkan Tuzcu, Hüsnü Fırat Altın, et al. · Pacing and Clinical Electrophysiology (2026) | TGRS Research Map | TGRS