Modelling and Correcting the Effects of Tremor on Touchscreen Interaction

Essential tremor and Parkinson’s tremor are common movement disorders, affecting approximately 7% of adults over 65, increasing with age. Although numerous studies have used keyboard timing, stand-alone sensors, or smartphone sensors to identify and measure tremor severity, relatively little research has isolated and examined how tremor impacts overall mobile interaction and usability models. This study investigated controlled fixed levels of induced tremor in a standardised ISO pointing task to quantify the effect on usability models of different levels of tremor. Tremor was induced using a wired glove delivering 4 Hz stimulation at 0, 15, 19, and 23 mA (approximating the range from slight to marked tremor). The results show that the Fitts’ throughput was 5.43 bps with no induced tremor, with reductions of 9.4%, 20.3%, and 28.9% at the active levels. Fitts’ law models showed high correlations that improved further when applying the Welford correction for tremor, supporting use of the adjustment when tremor is present. The study also indicates that machine-learned correction significantly improves touch accuracy when using smartphone sensors.

Authors

Institutions

Publication Details

Journal
Sensors
Published
2026-09-21
DOI
https://doi.org/10.3390/s26185981
Primary Topic
Neurological disorders and treatments
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
article

Modelling and Correcting the Effects of Tremor on Touchscreen Interaction

Ian Scott MacKenzie, Mark David Dunlop
Sensors
Neurological disorders and treatments
article

Modelling and Correcting the Effects of Tremor on Touchscreen Interaction

Ian Scott MacKenzie, Mark David Dunlop
article en

Abstract

Essential tremor and Parkinson’s tremor are common movement disorders, affecting approximately 7% of adults over 65, increasing with age. Although numerous studies have used keyboard timing, stand-alone sensors, or smartphone sensors to identify and measure tremor severity, relatively little research has isolated and examined how tremor impacts overall mobile interaction and usability models. This study investigated controlled fixed levels of induced tremor in a standardised ISO pointing task to quantify the effect on usability models of different levels of tremor. Tremor was induced using a wired glove delivering 4 Hz stimulation at 0, 15, 19, and 23 mA (approximating the range from slight to marked tremor). The results show that the Fitts’ throughput was 5.43 bps with no induced tremor, with reductions of 9.4%, 20.3%, and 28.9% at the active levels. Fitts’ law models showed high correlations that improved further when applying the Welford correction for tremor, supporting use of the adjustment when tremor is present. The study also indicates that machine-learned correction significantly improves touch accuracy when using smartphone sensors.

SensorsVol. 26(18)
University of Strathclyde (GB), York University (CA)
Peace, Justice and strong institutions
Openalex Percentile: Top 11%
Neurological disorders and treatments
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Modelling and Correcting the Effects of Tremor on Touchscreen Interaction — Ian Scott MacKenzie, Mark David Dunlop · Sensors (2026) | TGRS Research Map | TGRS