Verification of a Quantitative Risk Assessment Approach for Skin Sensitization Using EC1.6 Derived From LLNA: BrdU‐ELISA With Medical Devices

ABSTRACT Quantitative risk assessment (QRA) is a practical approach for establishing acceptable exposure levels (AELs) and estimating the risks of skin sensitizers in consumer and medical products; however, its verification using actual exposure condition remains limited. In this study, we verified the QRA approach based on EC1.6 values derived from local lymph node assay (LLNA): BrdU‐ELISA by leveraging contrasting clinical reports regarding isobornyl acrylate (IBOA), a known sensitizer, in two generations of continuous glucose monitors (CGMs). This study compared the original FreeStyle Libre, associated with reported incidences of allergic contact dermatitis (ACD) caused by IBOA, and the next‐generation FreeStyle Libre 2, for which no such cases have been reported. The point of departure (POD; μg/cm 2 ) was determined from a reliable EC1.6 value, and the AEL was subsequently derived using composite safety factors. For the original FreeStyle Libre, the estimated dermal exposure level of IBOA was approximately 17‐fold greater than the AEL, consistent with documented ACD incidences. Conversely, IBOA level in the FreeStyle Libre 2 was below the limit of quantification (LOQ). Even under conservative LOQ‐based assumptions, the estimated dermal exposure level of IBOA was approximately 1/70 of the AEL, aligning with the clinical absence of sensitization. These results demonstrate that the QRA approach using EC1.6 values effectively discriminates between products that do and do not cause ACD, supporting the validity and reliability of the QRA approach. This study highlights the importance of combining reliable hazard data with realistic exposure assessments to manage skin sensitization risks and inform safer product development.

Authors

Institutions

Publication Details

Journal
Journal of Applied Toxicology
Published
2026-09-21
DOI
https://doi.org/10.1002/jat.70447
Primary Topic
Contact Dermatitis and Allergies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
article

Verification of a Quantitative Risk Assessment Approach for Skin Sensitization Using EC1.6 Derived From LLNA: BrdU‐ELISA With Medical Devices

Kei Iwasaki, Aiko Tanabe, Ritsuko Katagiri, Yosuke Maeda et al.
Journal of Applied Toxicology
Contact Dermatitis and Allergies
article

Verification of a Quantitative Risk Assessment Approach for Skin Sensitization Using EC1.6 Derived From LLNA: BrdU‐ELISA With Medical Devices

Kei Iwasaki, Aiko Tanabe, Ritsuko Katagiri, Yosuke Maeda, Asako Fukushima, Masahiro Takeyoshi, Asako Sato
article en

Abstract

ABSTRACT Quantitative risk assessment (QRA) is a practical approach for establishing acceptable exposure levels (AELs) and estimating the risks of skin sensitizers in consumer and medical products; however, its verification using actual exposure condition remains limited. In this study, we verified the QRA approach based on EC1.6 values derived from local lymph node assay (LLNA): BrdU‐ELISA by leveraging contrasting clinical reports regarding isobornyl acrylate (IBOA), a known sensitizer, in two generations of continuous glucose monitors (CGMs). This study compared the original FreeStyle Libre, associated with reported incidences of allergic contact dermatitis (ACD) caused by IBOA, and the next‐generation FreeStyle Libre 2, for which no such cases have been reported. The point of departure (POD; μg/cm 2 ) was determined from a reliable EC1.6 value, and the AEL was subsequently derived using composite safety factors. For the original FreeStyle Libre, the estimated dermal exposure level of IBOA was approximately 17‐fold greater than the AEL, consistent with documented ACD incidences. Conversely, IBOA level in the FreeStyle Libre 2 was below the limit of quantification (LOQ). Even under conservative LOQ‐based assumptions, the estimated dermal exposure level of IBOA was approximately 1/70 of the AEL, aligning with the clinical absence of sensitization. These results demonstrate that the QRA approach using EC1.6 values effectively discriminates between products that do and do not cause ACD, supporting the validity and reliability of the QRA approach. This study highlights the importance of combining reliable hazard data with realistic exposure assessments to manage skin sensitization risks and inform safer product development.

Journal of Applied Toxicology
Chemicals Evaluation and Research Institute (JP)
Reduced inequalities
Openalex Percentile: Top 9%
Contact Dermatitis and Allergies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.