T-Rex: the transportable radon-222 explorer for environmental or public health studies

We describe the development and testing of a “suitcase sized” 100 L two-filter dual flow-loop radon monitor, weighing ∼18 kg, flow rate ∼5 L min −1 , Rn-222 sensitivity ∼0.02 s −1 ∙(Bq∙m −3 ) −1 , temporal resolution 30-min, and operational range ∼0.3 – 30,000 Bq∙m −3 . Its portability and sensitivity make it an ideal “crossover instrument” between the needs of the Public Health and Environmental research communities. Pending traceable calibration in a controlled climate chamber, here its performance was compared with a 200 L two-filter monitor (1.65 m tall, ∼80 kg), sampling outdoor air over 3 weeks during which radon varied between 0.14 Bq∙m −3 and 9.1 Bq∙m −3 . The distribution (10th/50th/90th percentile) of absolute hourly bias was 0.03/0.19/0.54 Bq∙m −3 . A separate comparison was made with an AlphaGUARD PQ2000 Pro and DF2000 over 8 days during which radon ranged from 0.6 Bq·m −3 to 9.9 Bq·m −3 . The reported 8-day average radon was 3.5 ± 1.97 Bq·m −3 (100 L monitor), 4.01 ± 2.92 Bq·m −3 (PQ2000 Pro) and 4.24 ± 2.65 Bq·m −3 (DF 2000). Daily mean absolute bias reached 1.7 Bq·m −3 , and absolute bias of 6-hourly means reached 3.2 Bq·m −3 . For the PQ2000 and DF 2000, hourly counting uncertainty reached 30 % at 6 Bq·m −3 and 4.5 Bq·m −3 , respectively (c.f. manufacturers reported detection limit of 2 Bq·m −3 ). The 100 L monitor reached 30 % counting uncertainty at 0.3 Bq·m −3 . While this does not meet the measurement criteria for Global Atmosphere Watch “baseline” monitoring (detection limit ≤0.05 Bq∙m −3 ), the monitor would be well suited for many environmental monitoring purposes and portable enough for indoor use.

Authors

Institutions

Publication Details

Journal
Journal of Environmental Radioactivity
Published
2026-09-22
DOI
https://doi.org/10.1016/j.jenvrad.2026.108169
Primary Topic
Radioactivity and Radon Measurements
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
article

T-Rex: the transportable radon-222 explorer for environmental or public health studies

Alan D. Griffiths, Scott D. Chambers, Ot Sisoutham, Raghav Hariharan et al.
Journal of Environmental Radioactivity
Radioactivity and Radon Measurements
article

T-Rex: the transportable radon-222 explorer for environmental or public health studies

Alan D. Griffiths, Scott D. Chambers, Ot Sisoutham, Raghav Hariharan, Cynthia Leung
article en

Abstract

We describe the development and testing of a “suitcase sized” 100 L two-filter dual flow-loop radon monitor, weighing ∼18 kg, flow rate ∼5 L min −1 , Rn-222 sensitivity ∼0.02 s −1 ∙(Bq∙m −3 ) −1 , temporal resolution 30-min, and operational range ∼0.3 – 30,000 Bq∙m −3 . Its portability and sensitivity make it an ideal “crossover instrument” between the needs of the Public Health and Environmental research communities. Pending traceable calibration in a controlled climate chamber, here its performance was compared with a 200 L two-filter monitor (1.65 m tall, ∼80 kg), sampling outdoor air over 3 weeks during which radon varied between 0.14 Bq∙m −3 and 9.1 Bq∙m −3 . The distribution (10th/50th/90th percentile) of absolute hourly bias was 0.03/0.19/0.54 Bq∙m −3 . A separate comparison was made with an AlphaGUARD PQ2000 Pro and DF2000 over 8 days during which radon ranged from 0.6 Bq·m −3 to 9.9 Bq·m −3 . The reported 8-day average radon was 3.5 ± 1.97 Bq·m −3 (100 L monitor), 4.01 ± 2.92 Bq·m −3 (PQ2000 Pro) and 4.24 ± 2.65 Bq·m −3 (DF 2000). Daily mean absolute bias reached 1.7 Bq·m −3 , and absolute bias of 6-hourly means reached 3.2 Bq·m −3 . For the PQ2000 and DF 2000, hourly counting uncertainty reached 30 % at 6 Bq·m −3 and 4.5 Bq·m −3 , respectively (c.f. manufacturers reported detection limit of 2 Bq·m −3 ). The 100 L monitor reached 30 % counting uncertainty at 0.3 Bq·m −3 . While this does not meet the measurement criteria for Global Atmosphere Watch “baseline” monitoring (detection limit ≤0.05 Bq∙m −3 ), the monitor would be well suited for many environmental monitoring purposes and portable enough for indoor use.

Journal of Environmental RadioactivityVol. 300
Australian Nuclear Science and Technology Organisation (AU)
Openalex Percentile: Top 10%
Radioactivity and Radon Measurements
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

T-Rex: the transportable radon-222 explorer for environmental or public health studies — Alan D. Griffiths, Scott D. Chambers, et al. · Journal of Environmental Radioactivity (2026) | TGRS Research Map | TGRS