Beyond the Short-Circuit Ratio: Control-Aware Online Assessment of Dynamic System Strength via Gray-Box Identification of Converter Dynamics

Conventional network-only short-circuit ratios (SCRs) do not quantify converter-control dependence or the reliability of a measurement-derived dynamic model. This paper combines an EMS network prior with structured converter identification, a return-difference margin, conditional uncertainty propagation, and event-dependent reporting. The unsigned margin is interpreted only with an independent stability check and a specified port normalization. The original IEEE 39-bus study is extended to include 1800 independent matched-model records, 1400 deliberate-mismatch trials, 1200 threshold-test records, repeated control changes, and coupled models at all three converter buses. Matched-model ellipsoid projections show 99–100% scalar-margin coverage, whereas direct scalar intervals show 91.5–97%, including one undercovered condition. A 0.1 ms relative measurement-channel delay gives zero ellipsoid coverage despite a median point error of 0.502%, establishing a measurement-calibration limitation. Three-converter coupling reduces the baseline margin from the independent-model value of 0.676 to 0.580. Under the same disturbance, two nominally stable PLL tunings produce voltage norms of 0.00818 and 0.01184, distinguishing their compliance with a specified 0.01 response limit. An event-triggered shorter-memory update combined with a complete post-event observation-window restart recovers all 24 tested changes within 12 s. The results support reliability-aware small-signal monitoring across the stated topologies and controller variants, while retaining explicit limitations on model mismatch, finite-band interpretation, and transfer to field or nonlinear converter behavior.

Authors

Institutions

Publication Details

Journal
Electronics
Published
2026-09-21
DOI
https://doi.org/10.3390/electronics15184340
Primary Topic
Power System Optimization and Stability
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
article

Beyond the Short-Circuit Ratio: Control-Aware Online Assessment of Dynamic System Strength via Gray-Box Identification of Converter Dynamics

Fan Li, Rui Shi, Jishuo Qin, Jialei Zhang et al.
Electronics
Power System Optimization and Stability
article

Beyond the Short-Circuit Ratio: Control-Aware Online Assessment of Dynamic System Strength via Gray-Box Identification of Converter Dynamics

Fan Li, Rui Shi, Jishuo Qin, Jialei Zhang, Dan Wang, Hanqing Liang
article en

Abstract

Conventional network-only short-circuit ratios (SCRs) do not quantify converter-control dependence or the reliability of a measurement-derived dynamic model. This paper combines an EMS network prior with structured converter identification, a return-difference margin, conditional uncertainty propagation, and event-dependent reporting. The unsigned margin is interpreted only with an independent stability check and a specified port normalization. The original IEEE 39-bus study is extended to include 1800 independent matched-model records, 1400 deliberate-mismatch trials, 1200 threshold-test records, repeated control changes, and coupled models at all three converter buses. Matched-model ellipsoid projections show 99–100% scalar-margin coverage, whereas direct scalar intervals show 91.5–97%, including one undercovered condition. A 0.1 ms relative measurement-channel delay gives zero ellipsoid coverage despite a median point error of 0.502%, establishing a measurement-calibration limitation. Three-converter coupling reduces the baseline margin from the independent-model value of 0.676 to 0.580. Under the same disturbance, two nominally stable PLL tunings produce voltage norms of 0.00818 and 0.01184, distinguishing their compliance with a specified 0.01 response limit. An event-triggered shorter-memory update combined with a complete post-event observation-window restart recovers all 24 tested changes within 12 s. The results support reliability-aware small-signal monitoring across the stated topologies and controller variants, while retaining explicit limitations on model mismatch, finite-band interpretation, and transfer to field or nonlinear converter behavior.

ElectronicsVol. 15(18)
North China Electric Power University (CN), State Grid Corporation of China (China) (CN)
Openalex Percentile: Top 21%
Power System Optimization and Stability
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Beyond the Short-Circuit Ratio: Control-Aware Online Assessment of Dynamic System Strength via Gray-Box Identification of Converter Dynamics — Fan Li, Rui Shi, et al. · Electronics (2026) | TGRS Research Map | TGRS