Intraday and Interday Repeatability of Laser Speckle Contrast Imaging for Ocular Blood Flow Measurement in Healthy Subjects

Purpose: To investigate the intra- and interday repeatability of ocular blood flow velocity index (BFVi) measurements using a laser speckle contrast imaging device. Methods: BFVi measurements were obtained using XyCAM CRE (Vasoptic Medical Inc., Columbia, MD). Two imaging sessions were performed on the same day (26 eyes) and on different days (20 eyes). For optic nerve head-centered datasets, the analyzed regions included the overall field of view, the optic disc, and a standard temporal peripapillary region. For macula-centered datasets, the regions analyzed were the overall field of view, the foveal avascular zone, and the perifoveal region. For each region, heart rate-adjusted measurements of the peak, dip, and mean BFVi were assessed. Results: For intraday measurements of all the optic nerve head-centered parameters, the coefficients of variation (CVs) ranged from 4.8% to 8.5%, and the intraclass correlation coefficient ranged from 0.74 to 0.98. For all macula-centered parameters, the CVs ranged from 4.7% to 6.2%, and the ICCs ranged from 0.93 to 0.98. For the interday measurements of all the optic nerve head-centered parameters, the CVs ranged from 7.9% to 12.6%, and the ICCs ranged from 0.56 to 0.93. For all the macula-centered parameters, the CVs ranged from 8.6% to 15.0%, and the intraclass correlation coefficient ranged from 0.79 to 0.94. Conclusions: Laser speckle contrast imaging demonstrated strong intraday repeatability and reliability for BFVi measurement in healthy subjects, with good interday reliability for key parameters despite some variability. Translational Relevance: Laser speckle contrast imaging shows promise for clinical use in ophthalmology due to its robust intraday and good interday reliability for ocular blood flow velocity measurements.

Authors

Institutions

Publication Details

Journal
Translational Vision Science & Technology
Published
2026-09-21
DOI
https://doi.org/10.1167/tvst.15.9.12
Primary Topic
Thermoregulation and physiological responses
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
article

Intraday and Interday Repeatability of Laser Speckle Contrast Imaging for Ocular Blood Flow Measurement in Healthy Subjects

X Wang, Giovana Rosa Gameiro, Shuya Wang, Mariam Moarefi et al.
Translational Vision Science & Technology
Thermoregulation and physiological responses
article

Intraday and Interday Repeatability of Laser Speckle Contrast Imaging for Ocular Blood Flow Measurement in Healthy Subjects

X Wang, Giovana Rosa Gameiro, Shuya Wang, Mariam Moarefi, Andrew Hoover, Hong Jiang, Jianhua Wang, Xiaogang Wang, Lian Duan
article en

Abstract

Purpose: To investigate the intra- and interday repeatability of ocular blood flow velocity index (BFVi) measurements using a laser speckle contrast imaging device. Methods: BFVi measurements were obtained using XyCAM CRE (Vasoptic Medical Inc., Columbia, MD). Two imaging sessions were performed on the same day (26 eyes) and on different days (20 eyes). For optic nerve head-centered datasets, the analyzed regions included the overall field of view, the optic disc, and a standard temporal peripapillary region. For macula-centered datasets, the regions analyzed were the overall field of view, the foveal avascular zone, and the perifoveal region. For each region, heart rate-adjusted measurements of the peak, dip, and mean BFVi were assessed. Results: For intraday measurements of all the optic nerve head-centered parameters, the coefficients of variation (CVs) ranged from 4.8% to 8.5%, and the intraclass correlation coefficient ranged from 0.74 to 0.98. For all macula-centered parameters, the CVs ranged from 4.7% to 6.2%, and the ICCs ranged from 0.93 to 0.98. For the interday measurements of all the optic nerve head-centered parameters, the CVs ranged from 7.9% to 12.6%, and the ICCs ranged from 0.56 to 0.93. For all the macula-centered parameters, the CVs ranged from 8.6% to 15.0%, and the intraclass correlation coefficient ranged from 0.79 to 0.94. Conclusions: Laser speckle contrast imaging demonstrated strong intraday repeatability and reliability for BFVi measurement in healthy subjects, with good interday reliability for key parameters despite some variability. Translational Relevance: Laser speckle contrast imaging shows promise for clinical use in ophthalmology due to its robust intraday and good interday reliability for ocular blood flow velocity measurements.

Translational Vision Science & TechnologyVol. 15(9)
University of Miami (US), Duke University (US), Shanxi Eye Hospital (CN), Shandong Provincial QianFoShan Hospital (CN), Shandong Shierming Eye Hospital (CN), Shandong Eye Hospital (CN), Shandong First Medical University (CN), Universidade Federal de São Paulo (BR)
Good health and well-being
Openalex Percentile: Top 11%
Thermoregulation and physiological responses
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.