Left ventricular ablation for ventricular tachycardia using a variable-loop circular pulsed field ablation catheter
Abstract Pulsed field ablation (PFA) has been increasingly used for ventricular ablation. We present a novel case describing use of a variable-loop circular PFA catheter (Varipulse, Biosense Webster, Inc., Irvine, CA, USA) via a retrograde aortic approach for left ventricular ventricular tachycardia ablation. Retrograde aortic access was achieved using a long sheath (Ventrax system, Merit Medical, South Jordan, UT) permitting safe unsheathing and manipulation of the variable-loop PFA catheter to avoid entrapment with the mitral valve apparatus. The procedure was completed without complication and no VT recurrence was observed over 3 months follow-up. This case highlights the feasibility of this approach and expands the potential applications of this integrated PFA platform beyond its current indication for atrial fibrillation ablation.
Authors
- Sania Jiwani (ORCID: https://orcid.org/0000-0001-7920-2577)
- Frank Bogun
- Jackson J. Liang
- Thomas A. Franzon
Institutions
- Bronson Methodist Hospital (US)
- University of Michigan (US)
- Michigan Medicine (US)
Publication Details
- Journal
- Journal of Interventional Cardiac Electrophysiology
- Published
- 2026-09-19
- DOI
- https://doi.org/10.1007/s10840-026-02441-4
- Primary Topic
- Cardiac Arrhythmias and Treatments
- Type
- article
- Field-Weighted Citation Impact
- 0.00