Left ventricular ablation for ventricular tachycardia using a variable-loop circular pulsed field ablation catheter

Abstract Pulsed field ablation (PFA) has been increasingly used for ventricular ablation. We present a novel case describing use of a variable-loop circular PFA catheter (Varipulse, Biosense Webster, Inc., Irvine, CA, USA) via a retrograde aortic approach for left ventricular ventricular tachycardia ablation. Retrograde aortic access was achieved using a long sheath (Ventrax system, Merit Medical, South Jordan, UT) permitting safe unsheathing and manipulation of the variable-loop PFA catheter to avoid entrapment with the mitral valve apparatus. The procedure was completed without complication and no VT recurrence was observed over 3 months follow-up. This case highlights the feasibility of this approach and expands the potential applications of this integrated PFA platform beyond its current indication for atrial fibrillation ablation.

Authors

Institutions

Publication Details

Journal
Journal of Interventional Cardiac Electrophysiology
Published
2026-09-19
DOI
https://doi.org/10.1007/s10840-026-02441-4
Primary Topic
Cardiac Arrhythmias and Treatments
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
article

Left ventricular ablation for ventricular tachycardia using a variable-loop circular pulsed field ablation catheter

Sania Jiwani, Frank Bogun, Jackson J. Liang, Thomas A. Franzon
Journal of Interventional Cardiac Electrophysiology
Cardiac Arrhythmias and Treatments
article

Left ventricular ablation for ventricular tachycardia using a variable-loop circular pulsed field ablation catheter

Sania Jiwani, Frank Bogun, Jackson J. Liang, Thomas A. Franzon
article en

Abstract

Abstract Pulsed field ablation (PFA) has been increasingly used for ventricular ablation. We present a novel case describing use of a variable-loop circular PFA catheter (Varipulse, Biosense Webster, Inc., Irvine, CA, USA) via a retrograde aortic approach for left ventricular ventricular tachycardia ablation. Retrograde aortic access was achieved using a long sheath (Ventrax system, Merit Medical, South Jordan, UT) permitting safe unsheathing and manipulation of the variable-loop PFA catheter to avoid entrapment with the mitral valve apparatus. The procedure was completed without complication and no VT recurrence was observed over 3 months follow-up. This case highlights the feasibility of this approach and expands the potential applications of this integrated PFA platform beyond its current indication for atrial fibrillation ablation.

Journal of Interventional Cardiac Electrophysiology
Bronson Methodist Hospital (US), University of Michigan (US), Michigan Medicine (US)
Good health and well-being
Openalex Percentile: Top 10%
Cardiac Arrhythmias and Treatments
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies