Moon's HemaLeaf 7° (Maple J-VHS-7): Technical Specification of a Numerically Specified Seven-Grade Colour Scale for Catheter-Monitored Gross Haematuria, version 2.2

This record defines the normative colorimetric specification of HemaLeaf 7°, a seven-grade visual reference for gross haematuria observed in the flowing segment of transparent catheter drainage tubing. Each grade is fixed as an sRGB coordinate (IEC 61966-2-1) with CIELAB reference values (D65, CIE 1931 2° observer). The document states CIEDE2000 inter-grade differences (adjacent range 9.72–34.04; no rank inversion across 21 pairs), strictly monotonic lightness, dichromacy simulations, viewing conditions, a display self-check, print quality-control criteria (per-swatch ΔE00 ≤ 3.0), a three-zone escalation framework of proposed default responses, scope limitations and prior art. It contains no human-subject data and makes no performance claims; empirical validation will be reported separately. Competing interest: the author has pending Korean trademark applications (40-2026-0068724, 40-2026-0068725) and a design registration under examination. The licence does not extend to these names or design rights.

Authors

Publication Details

Journal
Zenodo (CERN European Organization for Nuclear Research)
Published
2026-09-19
DOI
https://doi.org/10.5281/zenodo.22842217
Primary Topic
Central Venous Catheters and Hemodialysis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
article

Moon's HemaLeaf 7° (Maple J-VHS-7): Technical Specification of a Numerically Specified Seven-Grade Colour Scale for Catheter-Monitored Gross Haematuria, version 2.2

Hyun Joon Moon
Zenodo (CERN European Organization for Nuclear Research)
Central Venous Catheters and Hemodialysis
article

Moon's HemaLeaf 7° (Maple J-VHS-7): Technical Specification of a Numerically Specified Seven-Grade Colour Scale for Catheter-Monitored Gross Haematuria, version 2.2

Hyun Joon Moon
article en

Abstract

This record defines the normative colorimetric specification of HemaLeaf 7°, a seven-grade visual reference for gross haematuria observed in the flowing segment of transparent catheter drainage tubing. Each grade is fixed as an sRGB coordinate (IEC 61966-2-1) with CIELAB reference values (D65, CIE 1931 2° observer). The document states CIEDE2000 inter-grade differences (adjacent range 9.72–34.04; no rank inversion across 21 pairs), strictly monotonic lightness, dichromacy simulations, viewing conditions, a display self-check, print quality-control criteria (per-swatch ΔE00 ≤ 3.0), a three-zone escalation framework of proposed default responses, scope limitations and prior art. It contains no human-subject data and makes no performance claims; empirical validation will be reported separately. Competing interest: the author has pending Korean trademark applications (40-2026-0068724, 40-2026-0068725) and a design registration under examination. The licence does not extend to these names or design rights.

Zenodo (CERN European Organization for Nuclear Research)
Openalex Percentile: Top 7%
Central Venous Catheters and Hemodialysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Moon's HemaLeaf 7° (Maple J-VHS-7): Technical Specification of a Numerically Specified Seven-Grade Colour Scale for Catheter-Monitored Gross Haematuria, version 2.2 — Hyun Joon Moon · Zenodo (CERN European Organization for Nuclear Research) (2026) | TGRS Research Map | TGRS