A U-Net Transformer for magnetic resonance elastography

{"Abstract":[0],"Purpose":[1],"Magnetic":[2],"resonance":[3],"elastography":[4],"(MRE)":[5],"is":[6,19],"a":[7,47,84,98,149,178,187,197],"critical":[8],"non-invasive":[9],"modality":[10],"for":[11,181,191],"quantifying":[12],"tissue":[13],"stiffness,":[14],"but":[15],"its":[16],"clinical":[17,159,203],"utility":[18],"limited":[20],"by":[21],"the":[22,74,94,103,112,155,173],"high":[23],"computational":[24,166],"cost":[25],"and":[26,39,54,70,172],"noise":[27],"sensitivity":[28],"of":[29,107,115],"traditional":[30],"inversion":[31,37],"techniques,":[32],"such":[33],"as":[34],"algebraic":[35],"Helmholtz":[36],"(AHI)":[38],"finite":[40],"element":[41],"methods":[42],"(FEM).":[43],"This":[44],"study":[45],"proposes":[46],"high-performance":[48],"deep":[49],"learning":[50,144],"alternative":[51],"to":[52,82,157],"accelerate":[53],"stabilize":[55],"MRE":[56,183],"reconstruction.":[57],"Methods":[58],"We":[59],"developed":[60],"an":[61],"open-source,":[62],"physics-based":[63],"simulation":[64,175],"framework":[65,176],"that":[66,101,121,153],"pairs":[67],"realistic":[68],"liver":[69],"tumor":[71],"geometries":[72],"from":[73],"LiTS":[75],"dataset":[76],"with":[77,111,164],"clinically":[78],"informed":[79],"stiffness":[80],"priors":[81],"generate":[83],"large-scale":[85],"benchmark":[86],"dataset.":[87],"To":[88],"improve":[89],"reconstruction":[90,138],"accuracy,":[91],"we":[92,147],"introduce":[93],"U-Net":[95],"Transformer":[96],"(UNT),":[97],"novel":[99],"architecture":[100,134,171],"hybridizes":[102],"local":[104],"inductive":[105],"bias":[106],"convolutional":[108],"neural":[109,192],"networks":[110],"global":[113],"context-awareness":[114],"Transformers.":[116],"Results":[117],"Numerical":[118],"experiments":[119],"indicate":[120],"data-driven":[122],"training":[123,127],"consistently":[124],"outperforms":[125],"physics-informed":[126,150],"in":[128,206],"prediction":[129],"accuracy.":[130],"The":[131,169],"proposed":[132],"UNT":[133,170],"demonstrates":[135],"significantly":[136],"higher":[137],"accuracy":[139,163],"than":[140],"current":[141],"state-of-the-art":[142],"machine":[143],"models.":[145],"Additionally,":[146],"validated":[148,198],"fine-tuning":[151],"strategy":[152],"adapts":[154],"model":[156],"“sparse-data\\"":[158],"scenarios,":[160],"enhancing":[161],"patient-specific":[162],"minimal":[165],"overhead.":[167],"Conclusion":[168],"accompanying":[174],"establish":[177],"standardized":[179],"foundation":[180],"AI-driven":[182],"inversion.":[184],"By":[185],"providing":[186],"rigorous":[188],"performance":[189],"baseline":[190],"operators,":[193],"this":[194],"work":[195],"offers":[196],"pathway":[199],"toward":[200],"real-time,":[201],"AI-assisted":[202],"decision":[204],"support":[205],"radiological":[207],"diagnostics.":[208]}

Authors

Institutions

Publication Details

Journal
International Journal of Computer Assisted Radiology and Surgery
Published
2026-09-19
DOI
https://doi.org/10.1007/s11548-026-03790-1
Primary Topic
Ultrasound Imaging and Elastography
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
article

A U-Net Transformer for magnetic resonance elastography

Matthew W. Urban, Hadi Meidani, Weiheng Zhong
International Journal of Computer Assisted Radiology and Surgery
Ultrasound Imaging and Elastography
article

A U-Net Transformer for magnetic resonance elastography

Matthew W. Urban, Hadi Meidani, Weiheng Zhong
article en

Abstract

Abstract Purpose Magnetic resonance elastography (MRE) is a critical non-invasive modality for quantifying tissue stiffness, but its clinical utility is limited by the high computational cost and noise sensitivity of traditional inversion techniques, such as algebraic Helmholtz inversion (AHI) and finite element methods (FEM). This study proposes a high-performance deep learning alternative to accelerate and stabilize MRE reconstruction. Methods We developed an open-source, physics-based simulation framework that pairs realistic liver and tumor geometries from the LiTS dataset with clinically informed stiffness priors to generate a large-scale benchmark dataset. To improve reconstruction accuracy, we introduce the U-Net Transformer (UNT), a novel architecture that hybridizes the local inductive bias of convolutional neural networks with the global context-awareness of Transformers. Results Numerical experiments indicate that data-driven training consistently outperforms physics-informed training in prediction accuracy. The proposed UNT architecture demonstrates significantly higher reconstruction accuracy than current state-of-the-art machine learning models. Additionally, we validated a physics-informed fine-tuning strategy that adapts the model to “sparse-data" clinical scenarios, enhancing patient-specific accuracy with minimal computational overhead. Conclusion The UNT architecture and the accompanying simulation framework establish a standardized foundation for AI-driven MRE inversion. By providing a rigorous performance baseline for neural operators, this work offers a validated pathway toward real-time, AI-assisted clinical decision support in radiological diagnostics.

International Journal of Computer Assisted Radiology and Surgery
University of Illinois Urbana-Champaign (US), Mayo Clinic in Arizona (US)
Peace, Justice and strong institutions
Openalex Percentile: Top 11%
Ultrasound Imaging and Elastography
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.