Axillary right vein percutaneous ballooning in hemodialysis catheter replacement: A case report

Reliable vascular access remains a key point of hemodialysis therapy although each patient's journey through chronic kidney disease is unique. The 2019 Kidney Disease Outcomes Quality Initiative (KDOQI) vascular access guidelines introduced a patient-centered approach, emphasizing individualized vascular access planning based on each patient's clinical characteristics, comorbidities, life expectancy, and treatment goals. Vascular access troubleshooting is required when the creation of a native arteriovenous fistula or prosthetic graft is not feasible, necessitating the use of tunneled central venous catheters inserted into central veins such as the internal jugular, subclavian, axillary, or femoral ones. The internal jugular vein is generally considered the preferred access site. However, when its use is precluded by thrombosis, stenosis, or unfavorable cervical anatomy, the axillary vein represents a valuable alternative. In this report, we describe the replacement of a tunneled hemodialysis catheter in the right axillary vein following percutaneous balloon angioplasty of an early axillary vein stenosis that had developed 6 months after the first catheter placement. This strategy was adopted because all other upper central venous access sites were unavailable owing to right internal jugular vein stenosis and previous thrombosis of the brachiocephalic vein. Post-procedural chest radiography confirmed the correct positioning of the catheter tip within the right atrium site. The patient successfully resumed maintenance hemodialysis without further catheter dysfunction during follow-up. This case highlights the feasibility of percutaneous balloon angioplasty of a previously cannulated axillary vein to preserve vascular access and facilitate catheter replacement in hemodialysis patients with multiple comorbidities and severely limited central venous access options.

Authors

Institutions

Publication Details

Journal
The Journal of Vascular Access
Published
2026-09-18
DOI
https://doi.org/10.1177/11297298261476292
Primary Topic
Central Venous Catheters and Hemodialysis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
article

Axillary right vein percutaneous ballooning in hemodialysis catheter replacement: A case report

Filippo Aucella, Giovanni Ciccarese, Gaetano Ferrara, A. De Francesco et al.
The Journal of Vascular Access
Central Venous Catheters and Hemodialysis
article

Axillary right vein percutaneous ballooning in hemodialysis catheter replacement: A case report

Filippo Aucella, Giovanni Ciccarese, Gaetano Ferrara, A. De Francesco, Gatta Giuseppe, Nasuto Michelangelo
article en

Abstract

Reliable vascular access remains a key point of hemodialysis therapy although each patient's journey through chronic kidney disease is unique. The 2019 Kidney Disease Outcomes Quality Initiative (KDOQI) vascular access guidelines introduced a patient-centered approach, emphasizing individualized vascular access planning based on each patient's clinical characteristics, comorbidities, life expectancy, and treatment goals. Vascular access troubleshooting is required when the creation of a native arteriovenous fistula or prosthetic graft is not feasible, necessitating the use of tunneled central venous catheters inserted into central veins such as the internal jugular, subclavian, axillary, or femoral ones. The internal jugular vein is generally considered the preferred access site. However, when its use is precluded by thrombosis, stenosis, or unfavorable cervical anatomy, the axillary vein represents a valuable alternative. In this report, we describe the replacement of a tunneled hemodialysis catheter in the right axillary vein following percutaneous balloon angioplasty of an early axillary vein stenosis that had developed 6 months after the first catheter placement. This strategy was adopted because all other upper central venous access sites were unavailable owing to right internal jugular vein stenosis and previous thrombosis of the brachiocephalic vein. Post-procedural chest radiography confirmed the correct positioning of the catheter tip within the right atrium site. The patient successfully resumed maintenance hemodialysis without further catheter dysfunction during follow-up. This case highlights the feasibility of percutaneous balloon angioplasty of a previously cannulated axillary vein to preserve vascular access and facilitate catheter replacement in hemodialysis patients with multiple comorbidities and severely limited central venous access options.

The Journal of Vascular Access
Casa Sollievo della Sofferenza (IT)
Good health and well-being
Openalex Percentile: Top 7%
Central Venous Catheters and Hemodialysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.