Quantification of Caudal Osteointegration Surface Exposure after Uncemented Total Hip Replacement Stem Implantation: Effect of Stem Size and Implantation Depth

Abstract The objectives of this study are to quantify the area of exposed caudal osseointegration surface after implantation of Biomedtrix Biological Fixation (BFX) stems and study the effect of stem size and implantation depth on this measurement as well as to quantify caudal femoral bone defect changes during femoral canal preparation and stem exposure. This is an in vitro, original research. Using 10 canine femoral model specimens, an undersized, an appropriately sized, and an oversized uncemented BFX stems were implanted in each bone, using three-dimensional-printed guides, to three levels of progressive distalization. Measurements of porous surface exposure and caudal bone defect were obtained from photographs, for all stem sizes and implantation depth. In correctly sized, aligned, and distalized stems, 34.8% of the caudal porous surface remains exposed. Stem distalization significantly decreases caudal surface exposure for all stem sizes and increases the extent of the caudal femoral bone defect for all stem sizes. Complete, circumferential coverage of the proximal BFX stem is not possible. Stems should be properly distalized to reduce the exposed caudal integration surface while maintaining proper hip biomechanics. The caudal bone defect produced by femoral canal preparation progressively widens and migrates distally as stem size and depth increase. Familiarity with these features, not visible on a craniolateral approach, may be useful for surgeons performing canine uncemented hip replacement with the caudal approach.

Authors

Institutions

Publication Details

Journal
Veterinary and Comparative Orthopaedics and Traumatology
Published
2026-09-17
DOI
https://doi.org/10.1055/a-2956-1103
Primary Topic
Orthopaedic implants and arthroplasty
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
article

Quantification of Caudal Osteointegration Surface Exposure after Uncemented Total Hip Replacement Stem Implantation: Effect of Stem Size and Implantation Depth

Claudio Motta, Juan Marti, Marie F. Erwood, Rachel D.A. Malkani
Veterinary and Comparative Orthopaedics and Traumatology
Orthopaedic implants and arthroplasty
article

Quantification of Caudal Osteointegration Surface Exposure after Uncemented Total Hip Replacement Stem Implantation: Effect of Stem Size and Implantation Depth

Claudio Motta, Juan Marti, Marie F. Erwood, Rachel D.A. Malkani
article en

Abstract

Abstract The objectives of this study are to quantify the area of exposed caudal osseointegration surface after implantation of Biomedtrix Biological Fixation (BFX) stems and study the effect of stem size and implantation depth on this measurement as well as to quantify caudal femoral bone defect changes during femoral canal preparation and stem exposure. This is an in vitro, original research. Using 10 canine femoral model specimens, an undersized, an appropriately sized, and an oversized uncemented BFX stems were implanted in each bone, using three-dimensional-printed guides, to three levels of progressive distalization. Measurements of porous surface exposure and caudal bone defect were obtained from photographs, for all stem sizes and implantation depth. In correctly sized, aligned, and distalized stems, 34.8% of the caudal porous surface remains exposed. Stem distalization significantly decreases caudal surface exposure for all stem sizes and increases the extent of the caudal femoral bone defect for all stem sizes. Complete, circumferential coverage of the proximal BFX stem is not possible. Stems should be properly distalized to reduce the exposed caudal integration surface while maintaining proper hip biomechanics. The caudal bone defect produced by femoral canal preparation progressively widens and migrates distally as stem size and depth increase. Familiarity with these features, not visible on a craniolateral approach, may be useful for surgeons performing canine uncemented hip replacement with the caudal approach.

Veterinary and Comparative Orthopaedics and Traumatology
Electric Vehicle Transportation Center (US), Dermatology Specialists (US), Southern Oncology Specialists (US)
Openalex Percentile: Top 8%
Orthopaedic implants and arthroplasty
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Quantification of Caudal Osteointegration Surface Exposure after Uncemented Total Hip Replacement Stem Implantation: Effect of Stem Size and Implantation Depth — Claudio Motta, Juan Marti, et al. · Veterinary and Comparative Orthopaedics and Traumatology (2026) | TGRS Research Map | TGRS