Water and Liquid Soap Cleaning of Removable Orthodontic Appliances: A Triple‑Blind Randomized Crossover Study of Microbial Load Reduction

Background: To evaluate the effectiveness of water and a liquid soap solution compared with 0.2% chlorhexidine (CHX) mouthwash in reducing microbial load and microbial plaque formation on removable orthodontic appliances. Methods: Forty-two patients aged 9 to 16 years who had newly received acrylic resin removable orthodontic appliances were enrolled and randomized in a triple-blind crossover clinical trial. Thirty participants completed all study phases and were included in the final analysis. Participants were randomly allocated into 3 groups (n=10) according to the initial cleaning protocol: water, water plus liquid soap solution, or 0.2% CHX mouthwash. Each protocol was followed for one week, after which participants crossed over to the remaining protocols until all patients completed all 3 cleaning regimens. At the end of each intervention period, the plaque index (PI) of the removable appliances and the Streptococcus mutans microbial load were assessed. Results: Significant differences were observed among the 3 cleaning protocols in both qualitative and quantitative microbial assessments ( P <0.001). The highest mean microbial load was detected following cleaning with water alone, whereas the lowest microbial load was observed with 0.2% CHX mouthwash. Plaque index measurements were consistent with these findings. In the microbroth dilution assay, the minimum inhibitory concentration (MIC) against S. mutans was 32 μg/mL for 0.2% CHX mouthwash and >500 μg/mL for the liquid soap solution. Conclusions: Although water and liquid soap solution demonstrated lower antimicrobial activity than 0.2% CHX mouthwash, they were still effective in reducing plaque index scores and S. mutans load in patients using removable orthodontic appliances.

Authors

Institutions

Publication Details

Journal
Infectious Diseases in Clinical Practice
Published
2026-09-17
DOI
https://doi.org/10.1097/ipc.0000000000001657
Primary Topic
Dental materials and restorations
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
article

Water and Liquid Soap Cleaning of Removable Orthodontic Appliances: A Triple‑Blind Randomized Crossover Study of Microbial Load Reduction

Meysam Hasannejad‐Bibalan, Rashin Bahrami, Yasamin B. Hemmati, Bardia V. Saberi et al.
Infectious Diseases in Clinical Practice
Dental materials and restorations
article

Water and Liquid Soap Cleaning of Removable Orthodontic Appliances: A Triple‑Blind Randomized Crossover Study of Microbial Load Reduction

Meysam Hasannejad‐Bibalan, Rashin Bahrami, Yasamin B. Hemmati, Bardia V. Saberi, Mohadese Asli
article en

Abstract

Background: To evaluate the effectiveness of water and a liquid soap solution compared with 0.2% chlorhexidine (CHX) mouthwash in reducing microbial load and microbial plaque formation on removable orthodontic appliances. Methods: Forty-two patients aged 9 to 16 years who had newly received acrylic resin removable orthodontic appliances were enrolled and randomized in a triple-blind crossover clinical trial. Thirty participants completed all study phases and were included in the final analysis. Participants were randomly allocated into 3 groups (n=10) according to the initial cleaning protocol: water, water plus liquid soap solution, or 0.2% CHX mouthwash. Each protocol was followed for one week, after which participants crossed over to the remaining protocols until all patients completed all 3 cleaning regimens. At the end of each intervention period, the plaque index (PI) of the removable appliances and the Streptococcus mutans microbial load were assessed. Results: Significant differences were observed among the 3 cleaning protocols in both qualitative and quantitative microbial assessments ( P <0.001). The highest mean microbial load was detected following cleaning with water alone, whereas the lowest microbial load was observed with 0.2% CHX mouthwash. Plaque index measurements were consistent with these findings. In the microbroth dilution assay, the minimum inhibitory concentration (MIC) against S. mutans was 32 μg/mL for 0.2% CHX mouthwash and >500 μg/mL for the liquid soap solution. Conclusions: Although water and liquid soap solution demonstrated lower antimicrobial activity than 0.2% CHX mouthwash, they were still effective in reducing plaque index scores and S. mutans load in patients using removable orthodontic appliances.

Infectious Diseases in Clinical PracticeVol. 34(6)
Iran University of Medical Sciences (IR), Guilan University of Medical Sciences (IR)
Clean water and sanitation
Openalex Percentile: Top 9%
Dental materials and restorations
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.