Rapid Antimicrobial Susceptibility Testing Using Direct Centrifugation Significantly Reduces Turnaround Time While Maintaining High Diagnostic Accuracy in Bloodstream Infections

Background/Objectives: Bloodstream infection-associated sepsis and septic shock remain major causes of in-hospital mortality. Because conventional antimicrobial susceptibility testing (AST) requires 48–72 h, earlier susceptibility results may facilitate timely antimicrobial optimization. This study evaluated the performance and clinical utility of a direct centrifugation-based AST method compared with the standard workflow. Methods: A total of 328 monomicrobial positive blood culture isolates, comprising 168 Gram-negative bacteria and 160 Gram-positive cocci, were analyzed. Essential agreement (EA), categorical agreement (CA), very major errors (VMEs), major errors (MEs), minor errors (mEs), and turnaround time (TAT) were compared between the two methods. Results: For Gram-negative bacteria, the direct method achieved an EA of 97.77% and CA of 98.53%, with VME, ME, and mE rates of 0.81%, 0.14%, and 0.60%, respectively. Particularly high concordance was observed for Escherichia coli and Klebsiella pneumoniae. For Gram-positive cocci, the EA and CA were 93.29% and 95.91%, respectively, with VME, ME, and mE rates of 3.47%, 1.08%, and 0.94%, respectively. Although overall agreement remained high, the GPC VME rate slightly exceeded the predefined 3% criterion, and elevated species-specific VME rates were observed for several organisms. The direct centrifugation method significantly reduced the mean TAT from 48.74 to 25.13 h, corresponding to an approximately 23.61 h reduction. Conclusions: The direct centrifugation method substantially shortened AST reporting time while maintaining high overall agreement with the standard workflow, particularly for Gram-negative bacteria. Further validation is warranted for Gram-positive and organism–antimicrobial combinations associated with elevated VME rates before routine clinical implementation.

Authors

Institutions

Publication Details

Journal
Diagnostics
Published
2026-09-17
DOI
https://doi.org/10.3390/diagnostics16183007
Primary Topic
Bacterial Identification and Susceptibility Testing
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
article

Rapid Antimicrobial Susceptibility Testing Using Direct Centrifugation Significantly Reduces Turnaround Time While Maintaining High Diagnostic Accuracy in Bloodstream Infections

Swee-Siang Wong, Ming-Hsueh Tsai, Yu‐Che Cheng, Li-Min Chang et al.
Diagnostics
Bacterial Identification and Susceptibility Testing
article

Rapid Antimicrobial Susceptibility Testing Using Direct Centrifugation Significantly Reduces Turnaround Time While Maintaining High Diagnostic Accuracy in Bloodstream Infections

Swee-Siang Wong, Ming-Hsueh Tsai, Yu‐Che Cheng, Li-Min Chang, Ting-I Wu, Chien-Chun Yang, Wei-Shang Hsih, Chi-Yen Wong, Wen-Ling Yen, Ya-Yuan Mao
article en

Abstract

Background/Objectives: Bloodstream infection-associated sepsis and septic shock remain major causes of in-hospital mortality. Because conventional antimicrobial susceptibility testing (AST) requires 48–72 h, earlier susceptibility results may facilitate timely antimicrobial optimization. This study evaluated the performance and clinical utility of a direct centrifugation-based AST method compared with the standard workflow. Methods: A total of 328 monomicrobial positive blood culture isolates, comprising 168 Gram-negative bacteria and 160 Gram-positive cocci, were analyzed. Essential agreement (EA), categorical agreement (CA), very major errors (VMEs), major errors (MEs), minor errors (mEs), and turnaround time (TAT) were compared between the two methods. Results: For Gram-negative bacteria, the direct method achieved an EA of 97.77% and CA of 98.53%, with VME, ME, and mE rates of 0.81%, 0.14%, and 0.60%, respectively. Particularly high concordance was observed for Escherichia coli and Klebsiella pneumoniae. For Gram-positive cocci, the EA and CA were 93.29% and 95.91%, respectively, with VME, ME, and mE rates of 3.47%, 1.08%, and 0.94%, respectively. Although overall agreement remained high, the GPC VME rate slightly exceeded the predefined 3% criterion, and elevated species-specific VME rates were observed for several organisms. The direct centrifugation method significantly reduced the mean TAT from 48.74 to 25.13 h, corresponding to an approximately 23.61 h reduction. Conclusions: The direct centrifugation method substantially shortened AST reporting time while maintaining high overall agreement with the standard workflow, particularly for Gram-negative bacteria. Further validation is warranted for Gram-positive and organism–antimicrobial combinations associated with elevated VME rates before routine clinical implementation.

DiagnosticsVol. 16(18)
National Central University (TW), Cathay General Hospital (TW)
Good health and well-being
Openalex Percentile: Top 15%
Bacterial Identification and Susceptibility Testing
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.