ACPSEM guideline regarding the adoption of the IAEA TRS-398 Code of Practice Revision 1

Abstract The IAEA Technical Report Series 398 Code of Practice for the determination of absorbed dose in external beam radiotherapy was endorsed at the Engineers and Physical Scientists in Medicine (EPSM) conference in 2001 and has been widely adopted in Australia and New Zealand. This guideline provides recommendations from the Australasian College of Physical Scientists and Engineers in Medicine (ACPSEM) following the recent publication of TRS-398 Revision 1. It is jointly authored by the Australian Radiation Protection and Nuclear Safety Agency (ARPANSA), the Reference Dosimetry Advisory Group (RDAG) and the ACPSEM Radiation Oncology Specialty Group (ROSG). In addition to recommendations, the guideline discusses the implications of TRS-398 Revision 1 for the dosimetry of megavoltage photons, electrons and protons. TRS-398 Revision 1 is recommended for adoption in accordance with the recommendations provided in this guideline, including for FFF beams. For specialised FFF machines such as CyberKnife ® and TomoTherapy ® , and for Gamma Knife ® , the ACPSEM recommends the use of IAEA TRS-483 Code of Practice. MR linacs are covered by the ACPSEM position paper: dosimetry for magnetic resonance imaging linear accelerators and in AAPM TG-351. For kilovoltage photons, the recommendation to use the AAPM TG-61 protocol for radiotherapy sources is retained and now specifically also includes cabinet irradiators used in radiobiology.

Authors

Institutions

Publication Details

Journal
Physical and Engineering Sciences in Medicine
Published
2026-09-17
DOI
https://doi.org/10.1007/s13246-026-01795-3
Primary Topic
Radiation Therapy and Dosimetry
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
article

ACPSEM guideline regarding the adoption of the IAEA TRS-398 Code of Practice Revision 1

Robin Hill, Stewart Midgley, Scott Penfold, Alison Scott et al.
Physical and Engineering Sciences in Medicine
Radiation Therapy and Dosimetry
article

ACPSEM guideline regarding the adoption of the IAEA TRS-398 Code of Practice Revision 1

Robin Hill, Stewart Midgley, Scott Penfold, Alison Scott, Brendan Healy, Jöerg Lehmann, Jeffrey Barber, Rhonda Brown, Vaughan Moutrie, Allan Stewart, Brindha Subramanian, Duncan Butler, Daniel Truant, Madelaine Tyler, Andrew Alves, Peter Harty, Chris Oliver, Simon Berke
article en

Abstract

Abstract The IAEA Technical Report Series 398 Code of Practice for the determination of absorbed dose in external beam radiotherapy was endorsed at the Engineers and Physical Scientists in Medicine (EPSM) conference in 2001 and has been widely adopted in Australia and New Zealand. This guideline provides recommendations from the Australasian College of Physical Scientists and Engineers in Medicine (ACPSEM) following the recent publication of TRS-398 Revision 1. It is jointly authored by the Australian Radiation Protection and Nuclear Safety Agency (ARPANSA), the Reference Dosimetry Advisory Group (RDAG) and the ACPSEM Radiation Oncology Specialty Group (ROSG). In addition to recommendations, the guideline discusses the implications of TRS-398 Revision 1 for the dosimetry of megavoltage photons, electrons and protons. TRS-398 Revision 1 is recommended for adoption in accordance with the recommendations provided in this guideline, including for FFF beams. For specialised FFF machines such as CyberKnife ® and TomoTherapy ® , and for Gamma Knife ® , the ACPSEM recommends the use of IAEA TRS-483 Code of Practice. MR linacs are covered by the ACPSEM position paper: dosimetry for magnetic resonance imaging linear accelerators and in AAPM TG-351. For kilovoltage photons, the recommendation to use the AAPM TG-61 protocol for radiotherapy sources is retained and now specifically also includes cabinet irradiators used in radiobiology.

Physical and Engineering Sciences in Medicine
The University of Sydney (AU), Genesis HealthCare (US), Peter MacCallum Cancer Centre (AU), Gosford Hospital (AU), Auckland City Hospital (NZ), Shoalhaven District Memorial Hospital (AU), Sir Charles Gairdner Hospital (AU), Blacktown & Mount Druitt Hospital (AU), Cancer Australia (AU), Footscray Hospital (AU), Western Health (AU), Capital and Coast District Health Board (NZ), Westmead Institute (AU), Calvary Mater Newcastle Hospital (AU), South Western Sydney Local Health District (AU), Australian Radiation Protection and Nuclear Safety Agency, University of Newcastle Australia (AU)
Openalex Percentile: Top 12%
Radiation Therapy and Dosimetry
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.