An EV-Assisted Dual T-Type Inverter SAPF with Model Predictive Control for Advanced Power Quality Enhancement

In order to improve power quality in low-voltage distribution networks with nonlinear, distorted, and unbalanced loads, this research suggests an innovative design for Shunt Active Power Filters (SAPFs). Compared to conventional single-inverter SAPF structures, the improved method uses a combination of two T-Type three-level inverters operating in a parallel configuration to improve compensator performance, leading to a higher current-carrying capacity as well as better harmonic reduction and system scalability. The Synchronous Reference Frame (SRF) algorithm is used to extract reference currents in order to achieve the required accuracy of harmonic cancellation. In order to ensure both a quick response and a suitable switch state selection for compensatory current references, the Model Predictive Current Control (MPCC) technique is employed. To maintain the DC-link voltage at a steady level and guarantee its correct operation under rapidly fluctuating loading conditions, a Proportional Integral (PI) controller-based DC–DC converter is also utilized. Four real-time operational circumstances are used to verify the performance of the proposed method using MATLAB/Simulink R2023a (i) SAPF activation under nonlinear loading conditions, (ii) dynamic load variation, (iii) distorted and unbalanced operation, and (iv) grid voltage disturbances including sag and swell conditions. The simulation study’s results show that, in all of the previously indicated scenarios, the source current Total Harmonic Distortion (THD) is reduced and an almost unity power factor is maintained while maintaining a constant DC-link voltage. Furthermore, the obtained performance meets IEEE-519-2022 requirements, demonstrating the feasibility of the suggested SAPF with two inverters under high-load circumstances.

Authors

Institutions

Publication Details

Journal
Energies
Published
2026-09-17
DOI
https://doi.org/10.3390/en19184403
Primary Topic
Power Quality and Harmonics
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
article

An EV-Assisted Dual T-Type Inverter SAPF with Model Predictive Control for Advanced Power Quality Enhancement

Mario Versaci, Mohamed Elbar, Matilde Pietrafesa, Ahmed Elottri et al.
Energies
Power Quality and Harmonics
article

An EV-Assisted Dual T-Type Inverter SAPF with Model Predictive Control for Advanced Power Quality Enhancement

Mario Versaci, Mohamed Elbar, Matilde Pietrafesa, Ahmed Elottri, Євген Зайцев, Vladislav Kuchanskyy, Naas Charrak, Mohamed Djelbane
article en

Abstract

In order to improve power quality in low-voltage distribution networks with nonlinear, distorted, and unbalanced loads, this research suggests an innovative design for Shunt Active Power Filters (SAPFs). Compared to conventional single-inverter SAPF structures, the improved method uses a combination of two T-Type three-level inverters operating in a parallel configuration to improve compensator performance, leading to a higher current-carrying capacity as well as better harmonic reduction and system scalability. The Synchronous Reference Frame (SRF) algorithm is used to extract reference currents in order to achieve the required accuracy of harmonic cancellation. In order to ensure both a quick response and a suitable switch state selection for compensatory current references, the Model Predictive Current Control (MPCC) technique is employed. To maintain the DC-link voltage at a steady level and guarantee its correct operation under rapidly fluctuating loading conditions, a Proportional Integral (PI) controller-based DC–DC converter is also utilized. Four real-time operational circumstances are used to verify the performance of the proposed method using MATLAB/Simulink R2023a (i) SAPF activation under nonlinear loading conditions, (ii) dynamic load variation, (iii) distorted and unbalanced operation, and (iv) grid voltage disturbances including sag and swell conditions. The simulation study’s results show that, in all of the previously indicated scenarios, the source current Total Harmonic Distortion (THD) is reduced and an almost unity power factor is maintained while maintaining a constant DC-link voltage. Furthermore, the obtained performance meets IEEE-519-2022 requirements, demonstrating the feasibility of the suggested SAPF with two inverters under high-load circumstances.

EnergiesVol. 19(18)
National Academy of Sciences of Ukraine (UA), Ziane Achour University of Djelfa (DZ), Institute of Electrodynamics (UA), University of Reggio Calabria (IT)
Affordable and clean energy
Openalex Percentile: Top 21%
Power Quality and Harmonics
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.