Encoder-controlled functional electrical stimulator for stroke rehabilitation: a usability study

Numerous therapeutic interventions have been explored for stroke related dysfunctions with various degrees of success; however, rehabilitation of the stroke-affected upper limb and hand still remains a challenge. Focus has now shifted to rehabilitative training devices that augment neuroplasticity and improve motor control. This article discusses a usability study carried out on a novel device called the encoder-controlled FES. It uses flexion and extension of the unaffected wrist to control the delivery of stimulation to the stroke affected wrist, resulting in a mirrored activity of the unaffected wrist on the stroke-affected wrist. The hypothesis was that a combination of bilateral arm training and FES mediated mirrored wrist activity will help the brain to relearn the activity and improve motor control. A preliminary usability study was conducted to check the acceptability of the device being used in a clinical setting. The device was used by 20 patients with stroke and 15 occupational/physiotherapists in a single session each. After the session, patients filled in three feedback forms – the System Usability Scale (SUS), the User Experience Questionnaire (UEQ) and an EC-FES patient questionnaire; the therapists were given an EC-FES therapist questionnaire. The mean scores obtained for the SUS test and patient questionnaire were 74 ± 16.3, and 78.26 ± 8.54 respectively. All the questions in the UEQ were answered positively, conveying that the device meets participants expectations, and the mean score obtained for the therapist questionnaire was 75.3 ± 14.93. The scores suggest that the device may be useable in a clinical setting and paves the way for further definitive trials.

Authors

Institutions

Publication Details

Journal
Scientific Reports
Published
2026-09-17
DOI
https://doi.org/10.1038/s41598-026-61919-3
Primary Topic
Stroke Rehabilitation and Recovery
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
article

Encoder-controlled functional electrical stimulator for stroke rehabilitation: a usability study

Cassandra D Solomons, Suresh Annpatriciacatherine, Selvaraj Samuelkamaleshkumar, V. Shanmugasundaram et al.
Scientific Reports
Stroke Rehabilitation and Recovery
article

Encoder-controlled functional electrical stimulator for stroke rehabilitation: a usability study

Cassandra D Solomons, Suresh Annpatriciacatherine, Selvaraj Samuelkamaleshkumar, V. Shanmugasundaram, Henry Prakash Magimairaj, Sivakumar Balasubramanian
article en

Abstract

Numerous therapeutic interventions have been explored for stroke related dysfunctions with various degrees of success; however, rehabilitation of the stroke-affected upper limb and hand still remains a challenge. Focus has now shifted to rehabilitative training devices that augment neuroplasticity and improve motor control. This article discusses a usability study carried out on a novel device called the encoder-controlled FES. It uses flexion and extension of the unaffected wrist to control the delivery of stimulation to the stroke affected wrist, resulting in a mirrored activity of the unaffected wrist on the stroke-affected wrist. The hypothesis was that a combination of bilateral arm training and FES mediated mirrored wrist activity will help the brain to relearn the activity and improve motor control. A preliminary usability study was conducted to check the acceptability of the device being used in a clinical setting. The device was used by 20 patients with stroke and 15 occupational/physiotherapists in a single session each. After the session, patients filled in three feedback forms – the System Usability Scale (SUS), the User Experience Questionnaire (UEQ) and an EC-FES patient questionnaire; the therapists were given an EC-FES therapist questionnaire. The mean scores obtained for the SUS test and patient questionnaire were 74 ± 16.3, and 78.26 ± 8.54 respectively. All the questions in the UEQ were answered positively, conveying that the device meets participants expectations, and the mean score obtained for the therapist questionnaire was 75.3 ± 14.93. The scores suggest that the device may be useable in a clinical setting and paves the way for further definitive trials.

Scientific ReportsVol. 16(1)
Christian Medical College, Vellore (IN), Vellore Institute of Technology University (IN)
VIT University, Christian Medical College, Vellore
Good health and well-being
Openalex Percentile: Top 16%
Stroke Rehabilitation and Recovery
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.