Serotonin measurement by lab-on-a–contact lens in porcine and human tears

Stress-related endocrine responses are critical for understanding human performance and mental health. Conventional assessments rely heavily on subjective self-report questionnaires or invasive sampling such as venipuncture. Tears offer a noninvasive source of neurochemical biomarkers, including serotonin, a key regulator of stress and mood. However, real-time and continuous monitoring of tear serotonin has not yet been fully realized. Here, we present a reversible lab-on-a–contact lens platform that integrates a printable, stretchable ferrocene-based electrochemical sensor for in situ detection of serotonin in tear fluid. The device is fabricated on a soft hydrogel lens and uses an electrochemically refreshable redox surface to restore baseline between measurements. Calibration in artificial tears established a limit of detection of 72 picomolar and a dynamic range of 0.1 to 500 nanomolar. Function was maintained for more than 28 days in a tear-like environment and under repeated mechanical deformations (flipping, folding, stretching, and twisting), with stability confirmed by periodic redox cycling. Ocular safety and biocompatibility were demonstrated in a porcine eye model. In a chronic stress mouse model, tear serotonin concentrations inversely correlated with cortisol in both serum and tears, and a first-in-human pilot study further supported the relationship between tear serotonin and stress with off-line analysis by the lab-on-a–contact lens platform. This platform could enable applications in decentralized, noninvasive endocrine monitoring and holds promise as a clinically translatable tool for real-time mental health biomarker assessment.

Authors

Institutions

Publication Details

Journal
Science Translational Medicine
Published
2026-09-16
DOI
https://doi.org/10.1126/scitranslmed.adv9538
Primary Topic
Ocular Surface and Contact Lens
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
article

Serotonin measurement by lab-on-a–contact lens in porcine and human tears

Juchen Guo, Pete Kollbaum, Liangshu Liu, C B Zhang et al.
Science Translational Medicine
Ocular Surface and Contact Lens
article

Serotonin measurement by lab-on-a–contact lens in porcine and human tears

Juchen Guo, Pete Kollbaum, Liangshu Liu, C B Zhang, Dawn Meyer, Reihaneh Haghniaz, A. Janet Tomiyama, Aliesha D. O’Raw, Yangzhi Zhu, Jianjun Chen, Sang Won Lee, Minwoo Kim, Wenyi Zeng
article en

Abstract

Stress-related endocrine responses are critical for understanding human performance and mental health. Conventional assessments rely heavily on subjective self-report questionnaires or invasive sampling such as venipuncture. Tears offer a noninvasive source of neurochemical biomarkers, including serotonin, a key regulator of stress and mood. However, real-time and continuous monitoring of tear serotonin has not yet been fully realized. Here, we present a reversible lab-on-a–contact lens platform that integrates a printable, stretchable ferrocene-based electrochemical sensor for in situ detection of serotonin in tear fluid. The device is fabricated on a soft hydrogel lens and uses an electrochemically refreshable redox surface to restore baseline between measurements. Calibration in artificial tears established a limit of detection of 72 picomolar and a dynamic range of 0.1 to 500 nanomolar. Function was maintained for more than 28 days in a tear-like environment and under repeated mechanical deformations (flipping, folding, stretching, and twisting), with stability confirmed by periodic redox cycling. Ocular safety and biocompatibility were demonstrated in a porcine eye model. In a chronic stress mouse model, tear serotonin concentrations inversely correlated with cortisol in both serum and tears, and a first-in-human pilot study further supported the relationship between tear serotonin and stress with off-line analysis by the lab-on-a–contact lens platform. This platform could enable applications in decentralized, noninvasive endocrine monitoring and holds promise as a clinically translatable tool for real-time mental health biomarker assessment.

Science Translational MedicineVol. 18(867)
University of California, Riverside (US), University of Southern California (US), Sun Yat-sen University (CN), University of California, Los Angeles (US), Yonsei University (KR), Terasaki Foundation (US), Indiana University Bloomington (US), Stomatology Hospital (CN)
Good health and well-being
Openalex Percentile: Top 8%
Ocular Surface and Contact Lens
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.