D1.2 Design, characterization and optimization of hardware and readout circuit for biosensors

Deliverable D1.2 reports the work performed by NTUA in Task 1.4 for the design, integration, verification and packaging of the MOBILES electrochemical readout circuit. Development progressed from a benchtop Vertex.100mA reference setup to a portable reader based on the EmStat Pico Development Kit and controlled through PSTrace 5.13 software. The document focuses on the functional circuit architecture, WE/RE/CE electrode interfacing, USB communication and power, accessible sensor connectors, PCB mounting and the custom 3D-printed enclosure. CV and SWV measurements with the E2 aptasensor were used to verify the complete circuit-to-sensor chain.

Authors

Publication Details

Journal
Zenodo (CERN European Organization for Nuclear Research)
Published
2026-09-16
DOI
https://doi.org/10.5281/zenodo.22787515
Primary Topic
Electrochemical sensors and biosensors
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
article

D1.2 Design, characterization and optimization of hardware and readout circuit for biosensors

National Technical University of Athens
Zenodo (CERN European Organization for Nuclear Research)
Electrochemical sensors and biosensors
article

D1.2 Design, characterization and optimization of hardware and readout circuit for biosensors

National Technical University of Athens
article en

Abstract

Deliverable D1.2 reports the work performed by NTUA in Task 1.4 for the design, integration, verification and packaging of the MOBILES electrochemical readout circuit. Development progressed from a benchtop Vertex.100mA reference setup to a portable reader based on the EmStat Pico Development Kit and controlled through PSTrace 5.13 software. The document focuses on the functional circuit architecture, WE/RE/CE electrode interfacing, USB communication and power, accessible sensor connectors, PCB mounting and the custom 3D-printed enclosure. CV and SWV measurements with the E2 aptasensor were used to verify the complete circuit-to-sensor chain.

Zenodo (CERN European Organization for Nuclear Research)
Industry, innovation and infrastructure
Openalex Percentile: Top 20%
Electrochemical sensors and biosensors
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.