Retrieve-Then-Verify for Evaluating Evidence Support and Hallucination in Large Language Model–Generated Medical Information: Empirical Study

Background Despite high reported accuracy on clinical and evidence appraisal tasks, AI-generated medical information may lack explicit support from source documents. This creates challenges for digital health practitioners regarding transparency, auditability, and trust when AI systems are used for evidence synthesis, guideline development, and clinical knowledge management. Large language models (LLMs) can generate fluent and seemingly correct outputs, but existing evaluations often rely on agreement with human judgments and do not directly assess whether AI-generated content is grounded in underlying evidence. Objective This study measures evidence support and hallucination in AI-generated medical information by assessing the extent to which LLM-generated risk-of-bias assessments are supported by source clinical trial reports. Methods We evaluated 3 LLMs (GPT-5, OpenAI o3-mini, and GPT-3.5) on risk-of-bias (RoB 2) assessment using all 97 randomized controlled trials for which the source Cochrane systematic review provided complete human RoB 2 annotations and full-text reports were accessible, constituting the complete reference set. No train-validation split was applied; all 97 studies were used for evaluation. Model outputs were constrained to structured RoB 2 signaling questions and domain-level judgments. For each generated claim, relevant text passages were retrieved from trial reports using the Okapi BM25 (Best Matching 25) algorithm. A verification step assigned evidence verdicts (supported, contradicted, not found, or out of scope) with verbatim quotations. We quantified evidence support rates and conservative and strict hallucination rates. Task performance was evaluated using exact and binary accuracy, sensitivity, specificity, F1-score, Youden J, and agreement with human reviewers using Cohen κ and Fleiss κ. Results Binary accuracy of AI-generated risk-of-bias judgments was high across domains (90%-98%), whereas exact accuracy was substantially lower (42%-71%), reflecting frequent disagreements in severity classification despite correct directional classification. GPT-5 achieved the strongest overall performance, including perfect binary accuracy for overall risk-of-bias conclusions and the highest agreement with human reviewers (quadratic κ up to 0.81). However, evidence support rates across models ranged from only 60% to 65%, with conservative hallucination rates of 34%-37%. GPT-5 showed the highest mean evidence support (64.3%) and the lowest strict hallucination rate (35.7%). Mean top-1 BM25 retrieval scores were similar across models (approximately 30-31), suggesting that differences in hallucination were not primarily attributable to differences in retrieval strength. Conclusions AI-generated medical information can achieve high decision-level accuracy while still lacking documentary support in a substantial proportion of outputs. Measuring evidence support and hallucination reveals important limitations that are not captured by agreement metrics alone. Retrieval-based evidence verification provides a reproducible and transparent approach for evaluating the reliability of AI-generated medical information, with direct relevance to digital health practice, evidence-based medicine, and medical informatics.

Authors

Publication Details

Journal
JMIR AI
Published
2026-09-16
DOI
https://doi.org/10.2196/93761
Primary Topic
Artificial Intelligence in Healthcare and Education
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
article

Retrieve-Then-Verify for Evaluating Evidence Support and Hallucination in Large Language Model–Generated Medical Information: Empirical Study

Zhaohui Liang, Gisela Butera, Sameer Antani, Cynthia Sheffield
JMIR AI
Artificial Intelligence in Healthcare and Education
article

Retrieve-Then-Verify for Evaluating Evidence Support and Hallucination in Large Language Model–Generated Medical Information: Empirical Study

Zhaohui Liang, Gisela Butera, Sameer Antani, Cynthia Sheffield
article en

Abstract

Background Despite high reported accuracy on clinical and evidence appraisal tasks, AI-generated medical information may lack explicit support from source documents. This creates challenges for digital health practitioners regarding transparency, auditability, and trust when AI systems are used for evidence synthesis, guideline development, and clinical knowledge management. Large language models (LLMs) can generate fluent and seemingly correct outputs, but existing evaluations often rely on agreement with human judgments and do not directly assess whether AI-generated content is grounded in underlying evidence. Objective This study measures evidence support and hallucination in AI-generated medical information by assessing the extent to which LLM-generated risk-of-bias assessments are supported by source clinical trial reports. Methods We evaluated 3 LLMs (GPT-5, OpenAI o3-mini, and GPT-3.5) on risk-of-bias (RoB 2) assessment using all 97 randomized controlled trials for which the source Cochrane systematic review provided complete human RoB 2 annotations and full-text reports were accessible, constituting the complete reference set. No train-validation split was applied; all 97 studies were used for evaluation. Model outputs were constrained to structured RoB 2 signaling questions and domain-level judgments. For each generated claim, relevant text passages were retrieved from trial reports using the Okapi BM25 (Best Matching 25) algorithm. A verification step assigned evidence verdicts (supported, contradicted, not found, or out of scope) with verbatim quotations. We quantified evidence support rates and conservative and strict hallucination rates. Task performance was evaluated using exact and binary accuracy, sensitivity, specificity, F1-score, Youden J, and agreement with human reviewers using Cohen κ and Fleiss κ. Results Binary accuracy of AI-generated risk-of-bias judgments was high across domains (90%-98%), whereas exact accuracy was substantially lower (42%-71%), reflecting frequent disagreements in severity classification despite correct directional classification. GPT-5 achieved the strongest overall performance, including perfect binary accuracy for overall risk-of-bias conclusions and the highest agreement with human reviewers (quadratic κ up to 0.81). However, evidence support rates across models ranged from only 60% to 65%, with conservative hallucination rates of 34%-37%. GPT-5 showed the highest mean evidence support (64.3%) and the lowest strict hallucination rate (35.7%). Mean top-1 BM25 retrieval scores were similar across models (approximately 30-31), suggesting that differences in hallucination were not primarily attributable to differences in retrieval strength. Conclusions AI-generated medical information can achieve high decision-level accuracy while still lacking documentary support in a substantial proportion of outputs. Measuring evidence support and hallucination reveals important limitations that are not captured by agreement metrics alone. Retrieval-based evidence verification provides a reproducible and transparent approach for evaluating the reliability of AI-generated medical information, with direct relevance to digital health practice, evidence-based medicine, and medical informatics.

JMIR AIVol. 5
Quality Education
Openalex Percentile: Top 14%
Artificial Intelligence in Healthcare and Education
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.