Aging Study of the CMS ME0 Triple-GEM Detector for the HL-LHC Upgrade

The CMS ME0 Triple-GEM detector will operate in the high-background forward region of the HL-LHC and therefore requires validation of its stability under large accumulated charge. An accelerated X-ray aging study is presented for a localized sector of an ME0 detector with an irradiated area of 67.6 cm$^2$, operated with an Ar/CO2 (70/30) gas mixture. The irradiation was performed using an X-ray source at 40 kV and 80 $\\mu$A, while detector performance was monitored through periodic effective-gain measurements with temperature and pressure corrections applied. The expected accumulated charge for 10 years of HL-LHC operation corresponds to 7.9 C/cm$^2$, and the study is ongoing toward 15.8 C/cm$^2$. To date, the irradiated sector has accumulated 9.419 C/cm$^2$ over 141.6 h. The temperature and pressure corrected effective gain variation remained within 22.3% (relative standard deviation) across the full accumulated-charge range. No significant gain degradation was observed within the present exposure range. These results support the operational robustness of the CMS ME0 Triple-GEM detector and provide an important step toward its qualification for HL-LHC Phase-2 running.

Authors

Publication Details

Journal
CERN Document Server (European Organization for Nuclear Research)
Published
2026-09-14
Primary Topic
Particle Detector Development and Performance
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
article

Aging Study of the CMS ME0 Triple-GEM Detector for the HL-LHC Upgrade

CMS Collaboration
CERN Document Server (European Organization for Nuclear Research)
Particle Detector Development and Performance
article

Aging Study of the CMS ME0 Triple-GEM Detector for the HL-LHC Upgrade

CMS Collaboration
article en

Abstract

The CMS ME0 Triple-GEM detector will operate in the high-background forward region of the HL-LHC and therefore requires validation of its stability under large accumulated charge. An accelerated X-ray aging study is presented for a localized sector of an ME0 detector with an irradiated area of 67.6 cm$^2$, operated with an Ar/CO2 (70/30) gas mixture. The irradiation was performed using an X-ray source at 40 kV and 80 $\mu$A, while detector performance was monitored through periodic effective-gain measurements with temperature and pressure corrections applied. The expected accumulated charge for 10 years of HL-LHC operation corresponds to 7.9 C/cm$^2$, and the study is ongoing toward 15.8 C/cm$^2$. To date, the irradiated sector has accumulated 9.419 C/cm$^2$ over 141.6 h. The temperature and pressure corrected effective gain variation remained within 22.3% (relative standard deviation) across the full accumulated-charge range. No significant gain degradation was observed within the present exposure range. These results support the operational robustness of the CMS ME0 Triple-GEM detector and provide an important step toward its qualification for HL-LHC Phase-2 running.

CERN Document Server (European Organization for Nuclear Research)
Openalex Percentile: Top 12%
Particle Detector Development and Performance
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Aging Study of the CMS ME0 Triple-GEM Detector for the HL-LHC Upgrade — CMS Collaboration · CERN Document Server (European Organization for Nuclear Research) (2026) | TGRS Research Map | TGRS