Qualitative analysis and clinical implications of lipid layer thickness variability: A retrospective, cross-sectional study

Meibomian gland (MG) dysfunction impairs the tear film lipid layer, which is critical for preventing aqueous evaporation and maintaining tear film stability. While a LipiView® II-reported mean lipid layer thickness (LLT) of ≥100 nm indicates a high- or ceiling-range device output rather than a calibrated absolute LLT, mean LLT alone may overlook clinically relevant information about the dynamic behavior of the tear film. This study aimed to evaluate whether qualitative variability in 20-s LipiView® II dynamic LLT traces is associated with MG morphology and ocular surface findings in eyes with device-reported high-range LLT values. In this retrospective, cross-sectional study, we analyzed 20-s dynamic LipiView® II recordings from eyes that were initially measured to have a mean LLT of ≥100 nm. Two masked observers classified LLT pattern variability as high or low based on predefined criteria. Clinical and demographic differences between the high- and low-variability groups were assessed statistically. Out of 85 eyes, 58 (68.2%) and 27 (31.8%) exhibited high- and low-variability, respectively. The high-variability group demonstrated markedly elevated meiboscores compared to the low-variability group, indicating a greater degree of MG dropouts ( p = 0.042). Besides elevated meiboscores, patients in the high-variability group suffered from substantially worse dry eye disease (DED) symptoms, a trend toward higher corneal and conjunctival staining scores, and significantly increased blinking frequency ( p < 0.05). Qualitative evaluation of LLT revealed increased meiboscores, greater severity of DED symptoms, and increased blinking frequency even in eyes with device-reported high-range mean LLT. LLT pattern analysis may warrant evaluation as an adjunctive approach for the early detection and targeted management of MG dysfunction-related evaporative DED.

Authors

Institutions

Publication Details

Journal
PLoS ONE
Published
2026-09-15
DOI
https://doi.org/10.1371/journal.pone.0357020
Primary Topic
Ocular Surface and Contact Lens
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
article

Qualitative analysis and clinical implications of lipid layer thickness variability: A retrospective, cross-sectional study

Ho Sik Hwang, Kyung‐Sun Na, Woong-Joo Whang, Jiyoung Emily Lee et al.
PLoS ONE
Ocular Surface and Contact Lens
article

Qualitative analysis and clinical implications of lipid layer thickness variability: A retrospective, cross-sectional study

Ho Sik Hwang, Kyung‐Sun Na, Woong-Joo Whang, Jiyoung Emily Lee, Reiko Arita, Eun Chul Kim, Hye Yeon Yoon, Hyun-Seung Kim, Dong-Kyu Kim
article en

Abstract

Meibomian gland (MG) dysfunction impairs the tear film lipid layer, which is critical for preventing aqueous evaporation and maintaining tear film stability. While a LipiView® II-reported mean lipid layer thickness (LLT) of ≥100 nm indicates a high- or ceiling-range device output rather than a calibrated absolute LLT, mean LLT alone may overlook clinically relevant information about the dynamic behavior of the tear film. This study aimed to evaluate whether qualitative variability in 20-s LipiView® II dynamic LLT traces is associated with MG morphology and ocular surface findings in eyes with device-reported high-range LLT values. In this retrospective, cross-sectional study, we analyzed 20-s dynamic LipiView® II recordings from eyes that were initially measured to have a mean LLT of ≥100 nm. Two masked observers classified LLT pattern variability as high or low based on predefined criteria. Clinical and demographic differences between the high- and low-variability groups were assessed statistically. Out of 85 eyes, 58 (68.2%) and 27 (31.8%) exhibited high- and low-variability, respectively. The high-variability group demonstrated markedly elevated meiboscores compared to the low-variability group, indicating a greater degree of MG dropouts ( p = 0.042). Besides elevated meiboscores, patients in the high-variability group suffered from substantially worse dry eye disease (DED) symptoms, a trend toward higher corneal and conjunctival staining scores, and significantly increased blinking frequency ( p < 0.05). Qualitative evaluation of LLT revealed increased meiboscores, greater severity of DED symptoms, and increased blinking frequency even in eyes with device-reported high-range mean LLT. LLT pattern analysis may warrant evaluation as an adjunctive approach for the early detection and targeted management of MG dysfunction-related evaporative DED.

PLoS ONEVol. 21(9)
Keio University (JP), The Catholic University of Korea Yeouido St. Mary's Hospital (KR), The Catholic University of Korea Bucheon St. Mary's Hospital (KR), Itochu (Japan) (JP), The Catholic University of Korea Seoul St. Mary's Hospital (KR), Catholic University of Korea (KR)
Openalex Percentile: Top 8%
Ocular Surface and Contact Lens
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.