Impedance-based tracking of a cochlear implant electrode reliably detects successful array insertion

Abstract Introduction Continuous impedance measurements during cochlear implantation have been hypothesized to provide a reliable indication if the electrode is inside or outside the cochlea. Therefore they provide a valuable feedback mechanism for successful insertion to the surgeon. This study aims to investigate whether impedances can be used to reliably detect successful insertion of the cochlear -implant electrode array. Methods In a prospective cross-sectional single-center study patients undergoing cochlear implantation with flexible lateral wall arrays (MED-EL, Innsbruck, Austria) were recruited between June 2022 and May 2023. Continuous impedance telemetry during electrode array insertion was obtained and compared to the ground truth of visual and audiological feedback by the surgeon. Results 34 patients (23 women, 11 men;, 16 left ears, 18 right ears) with a mean age of 52.8 years (SD 19.6 years) were included. The present study found a reliability of 88.9% comparing the algorithm of continuous insertion to the ground truth. Conclusions Continuous impedance measurements show a high reliability to detect the insertion of electrode contacts of a cochlear implant electrode array. The data collected by the software are suitable to detect misplacements already during insertion. This method is a promising approach to intraoperatively monitor successful insertion and offers the opportunity to replace fluoroscopy and radiological imaging in the aftercare of cochlear implant surgery.

Authors

Institutions

Publication Details

Journal
European Archives of Oto-Rhino-Laryngology
Published
2026-09-16
DOI
https://doi.org/10.1007/s00405-026-10464-w
Primary Topic
Hearing Loss and Rehabilitation
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
article

Impedance-based tracking of a cochlear implant electrode reliably detects successful array insertion

Tabita Breitsprecher, Angelika Dierker, Stefan Dazert, Joachim Schmutzhard et al.
European Archives of Oto-Rhino-Laryngology
Hearing Loss and Rehabilitation
article

Impedance-based tracking of a cochlear implant electrode reliably detects successful array insertion

Tabita Breitsprecher, Angelika Dierker, Stefan Dazert, Joachim Schmutzhard, Aline Föger, Stefan Hans, Nora M. Weiss
article en

Abstract

Abstract Introduction Continuous impedance measurements during cochlear implantation have been hypothesized to provide a reliable indication if the electrode is inside or outside the cochlea. Therefore they provide a valuable feedback mechanism for successful insertion to the surgeon. This study aims to investigate whether impedances can be used to reliably detect successful insertion of the cochlear -implant electrode array. Methods In a prospective cross-sectional single-center study patients undergoing cochlear implantation with flexible lateral wall arrays (MED-EL, Innsbruck, Austria) were recruited between June 2022 and May 2023. Continuous impedance telemetry during electrode array insertion was obtained and compared to the ground truth of visual and audiological feedback by the surgeon. Results 34 patients (23 women, 11 men;, 16 left ears, 18 right ears) with a mean age of 52.8 years (SD 19.6 years) were included. The present study found a reliability of 88.9% comparing the algorithm of continuous insertion to the ground truth. Conclusions Continuous impedance measurements show a high reliability to detect the insertion of electrode contacts of a cochlear implant electrode array. The data collected by the software are suitable to detect misplacements already during insertion. This method is a promising approach to intraoperatively monitor successful insertion and offers the opportunity to replace fluoroscopy and radiological imaging in the aftercare of cochlear implant surgery.

European Archives of Oto-Rhino-Laryngology
Innsbruck Medical University (AT), Universität Hamburg (DE), TUM Klinikum (DE), St. Elisabeth-Hospital Bochum (DE), University Medical Center Hamburg-Eppendorf (DE), Erbe Elektromedizin (Germany) (DE), MED-EL (Austria) (AT), Ruhr University Bochum (DE)
Openalex Percentile: Top 9%
Hearing Loss and Rehabilitation
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.