Methodological considerations regarding dorsal cortex drilling in distal radius fracture surgery: a critical appraisal on “Is dorsal cortex drilling necessary for distal radius fractures treated with a volar locking plate? A comparative study of near

Purpose: This study aimed to compare and analyze the effectiveness of near-cortex-only drilling for the surgical treatment of distal radius fractures using a volar locking plate.Methods: From January 2010 to December 2022, a total of 185 patients aged 60 years or older with AO type C distal radius fractures who were treated with a volar locking plate at our hospital were enrolled.Of these, 59 patients were excluded according to the study criteria, resulting in a final cohort of 126 subjects.Without differentiating between left and right sides, group A (n=60) underwent distal locking screw fixation with screws of 12-mm length (except for the most radial screw) using near-cortex-only drilling.In group B (n=66), drilling was performed through to the dorsal cortex, and the length was measured using a depth gauge; distal screws were then fixed at a length 2 mm shorter than the measured depth.The degree of fracture reduction on postoperative radiographs was assessed using the modified Lidstrom scoring system by measuring radial inclination, radial height, and volar tilt.In addition, the visual analog scale, the Korean Disabilities of the Arm, Shoulder, and Hand (DASH) score, and the incidence of extensor tendon rupture and tenosynovitis were evaluated at the final follow-up and compared between groups.Results: Bone union was achieved in all cases, with no significant radiographic differences observed between the two groups (P>0.05).In contrast, two cases of extensor tenosynovitis were noted in group A, whereas group B experienced one extensor tendon rupture and five cases of extensor tenosynovitis, representing a significant difference (P<0.05).Conclusions: In patients aged 60 years or older with AO type C distal radius fractures, the technique of near-cortex-only drilling with short distal locking screws yielded satisfactory results for fracture reduction and clinical indices.This approach may offer a new alternative for preventing extensor tendon rupture or tenosynovitis.

Authors

Institutions

Publication Details

Journal
Journal of Trauma and Injury
Published
2026-09-15
DOI
https://doi.org/10.20408/jti.2025.0261
Primary Topic
Orthopedic Surgery and Rehabilitation
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
article

Methodological considerations regarding dorsal cortex drilling in distal radius fracture surgery: a critical appraisal on “Is dorsal cortex drilling necessary for distal radius fractures treated with a volar locking plate? A comparative study of near

Ahmet Acar
Journal of Trauma and Injury
Orthopedic Surgery and Rehabilitation
article

Methodological considerations regarding dorsal cortex drilling in distal radius fracture surgery: a critical appraisal on “Is dorsal cortex drilling necessary for distal radius fractures treated with a volar locking plate? A comparative study of near

Ahmet Acar
article en

Abstract

Purpose: This study aimed to compare and analyze the effectiveness of near-cortex-only drilling for the surgical treatment of distal radius fractures using a volar locking plate.Methods: From January 2010 to December 2022, a total of 185 patients aged 60 years or older with AO type C distal radius fractures who were treated with a volar locking plate at our hospital were enrolled.Of these, 59 patients were excluded according to the study criteria, resulting in a final cohort of 126 subjects.Without differentiating between left and right sides, group A (n=60) underwent distal locking screw fixation with screws of 12-mm length (except for the most radial screw) using near-cortex-only drilling.In group B (n=66), drilling was performed through to the dorsal cortex, and the length was measured using a depth gauge; distal screws were then fixed at a length 2 mm shorter than the measured depth.The degree of fracture reduction on postoperative radiographs was assessed using the modified Lidstrom scoring system by measuring radial inclination, radial height, and volar tilt.In addition, the visual analog scale, the Korean Disabilities of the Arm, Shoulder, and Hand (DASH) score, and the incidence of extensor tendon rupture and tenosynovitis were evaluated at the final follow-up and compared between groups.Results: Bone union was achieved in all cases, with no significant radiographic differences observed between the two groups (P>0.05).In contrast, two cases of extensor tenosynovitis were noted in group A, whereas group B experienced one extensor tendon rupture and five cases of extensor tenosynovitis, representing a significant difference (P<0.05).Conclusions: In patients aged 60 years or older with AO type C distal radius fractures, the technique of near-cortex-only drilling with short distal locking screws yielded satisfactory results for fracture reduction and clinical indices.This approach may offer a new alternative for preventing extensor tendon rupture or tenosynovitis.

Journal of Trauma and Injury
University of Health Science (KH), Sağlık Bilimleri Üniversitesi (TR), University of Health Sciences Antigua (AG)
Openalex Percentile: Top 8%
Orthopedic Surgery and Rehabilitation
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.