Nano spray-dried powders for efficient pulmonary delivery of proteins: an emphasis on comparisons of derived metrics determined by chapters <601> and <1604>

(in unit percentage), of only 49.9% and 18.7% for the leucine-free ACL0, while significantly increased to 82.1% and 33.1% for ACL15, and further increased to >88% and >41% for ACL30/ACL45. The USP Chapters of traditional <601> and newly published <1604> were employed to determine derived metrics for aerodynamic particle size distribution (APSD). It was demonstrated that the authenticity of fitted values calculated in Chapter <601> was severely influenced by APSD profiles, and the fitted values can have immense differences from the actual values determined in Chapter <1604> . The differences can be minimized when the APSD is unimodal and normal across sized impactor stages. Hence, the authenticity of the fitted values can be improved. These new data deepen the understanding of APSD analyses and generate insights into the improvement of value authenticity for derived metrics, henceforward facilitating continuous improvements in quality control of inhaled products.

Authors

Institutions

Publication Details

Journal
Drug Delivery
Published
2026-09-15
DOI
https://doi.org/10.1080/10717544.2026.2732440
Primary Topic
Inhalation and Respiratory Drug Delivery
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
article

Nano spray-dried powders for efficient pulmonary delivery of proteins: an emphasis on comparisons of derived metrics determined by chapters <601> and <1604>

Jing Guo, Hao-Ying Li
Drug Delivery
Inhalation and Respiratory Drug Delivery
article

Nano spray-dried powders for efficient pulmonary delivery of proteins: an emphasis on comparisons of derived metrics determined by chapters <601> and <1604>

Jing Guo, Hao-Ying Li
article en

Abstract

(in unit percentage), of only 49.9% and 18.7% for the leucine-free ACL0, while significantly increased to 82.1% and 33.1% for ACL15, and further increased to >88% and >41% for ACL30/ACL45. The USP Chapters of traditional <601> and newly published <1604> were employed to determine derived metrics for aerodynamic particle size distribution (APSD). It was demonstrated that the authenticity of fitted values calculated in Chapter <601> was severely influenced by APSD profiles, and the fitted values can have immense differences from the actual values determined in Chapter <1604> . The differences can be minimized when the APSD is unimodal and normal across sized impactor stages. Hence, the authenticity of the fitted values can be improved. These new data deepen the understanding of APSD analyses and generate insights into the improvement of value authenticity for derived metrics, henceforward facilitating continuous improvements in quality control of inhaled products.

Drug DeliveryVol. 33(1)
King's College London (GB), Soochow University (TW)
Natural Science Foundation of Jiangsu Province
Zero hunger
Openalex Percentile: Top 12%
Inhalation and Respiratory Drug Delivery
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Nano spray-dried powders for efficient pulmonary delivery of proteins: an emphasis on comparisons of derived metrics determined by chapters <601> and <1604> — Jing Guo, Hao-Ying Li · Drug Delivery (2026) | TGRS Research Map | TGRS