Poor knot security when closing running sutures with three threads

Background: Knot security varies with half-knot and half-hitch sequences, rotation sense, and the type and diameter of sutures. Objectives: To evaluate the security of knots with three threads, as used for tying off running sutures. Methods: Three-way randomised experiments, with a factorial design and 10 knots/cell. The first experiment evaluated the knot security of a surgical knot (H2H1sH1s) for single stitches (2 threads) or running sutures (3 threads), using polyglactin 910 or polydioxanone, of 2-0 or 1 diameter. The second experiment evaluated the knot security of a running suture with 4 or 5 half-hitch sequences and 2 or 3 blocking knots, using polyglactin 910 or polydioxanone, and with diameters of 2-0 or 1. Main Outcome Measures: Knot security in Newton, measured with a digital dynamometer. With increasing forces, the knot either slipped open or blocked, causing the suture to break. Results: <0.0001), but not with suture diameter (three-way analysis of variance). Variability in outcome was greater with running sutures, especially with monofilament sutures of larger diameter. The second experiment demonstrated that half-hitch sequences occasionally opened with low forces, especially with larger monofilament sutures. Conclusions: Compared to knots tied with two threads, knots with three threads have a lower and more variable knot security, especially with larger monofilament sutures. What is New?: Knots with 3 threads should be avoided, as they may occasionally open with forces below 30 or 10 Newton.

Authors

Institutions

Publication Details

Journal
Facts Views and Vision in ObGyn
Published
2026-09-14
DOI
https://doi.org/10.52054/fvvo.2026.284
Primary Topic
Surgical Sutures and Adhesives
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
article

Poor knot security when closing running sutures with three threads

Anastasia Ussia, Arnaud Wattiez, William Kondo, Maurizio Giarola et al.
Facts Views and Vision in ObGyn
Surgical Sutures and Adhesives
article

Poor knot security when closing running sutures with three threads

Anastasia Ussia, Arnaud Wattiez, William Kondo, Maurizio Giarola, Philippe R. Koninckx, Bedayah Amro, Armondo Romeo, Leila Adamyan
article en

Abstract

Background: Knot security varies with half-knot and half-hitch sequences, rotation sense, and the type and diameter of sutures. Objectives: To evaluate the security of knots with three threads, as used for tying off running sutures. Methods: Three-way randomised experiments, with a factorial design and 10 knots/cell. The first experiment evaluated the knot security of a surgical knot (H2H1sH1s) for single stitches (2 threads) or running sutures (3 threads), using polyglactin 910 or polydioxanone, of 2-0 or 1 diameter. The second experiment evaluated the knot security of a running suture with 4 or 5 half-hitch sequences and 2 or 3 blocking knots, using polyglactin 910 or polydioxanone, and with diameters of 2-0 or 1. Main Outcome Measures: Knot security in Newton, measured with a digital dynamometer. With increasing forces, the knot either slipped open or blocked, causing the suture to break. Results: <0.0001), but not with suture diameter (three-way analysis of variance). Variability in outcome was greater with running sutures, especially with monofilament sutures of larger diameter. The second experiment demonstrated that half-hitch sequences occasionally opened with low forces, especially with larger monofilament sutures. Conclusions: Compared to knots tied with two threads, knots with three threads have a lower and more variable knot security, especially with larger monofilament sutures. What is New?: Knots with 3 threads should be avoided, as they may occasionally open with forces below 30 or 10 Newton.

Facts Views and Vision in ObGynVol. 18(3)
Università Cattolica del Sacro Cuore (IT), Moscow State University of Medicine and Dentistry (RU), Latifa Hospital (AE), University of Oxford (GB), National Medical Research Center for Obstetrics, Gynecology and Perinatology named after Academician V.I.Kulakov of the Ministry of Healthcare of the Russian Federation (RU), Ospedale Sant'Anna (IT), St. Anna Hospital (DE), Universidade Federal do Paraná (BR), University of Turin (IT), Université de Strasbourg (FR), Universidad del Rosario (CO), KU Leuven (BE)
Openalex Percentile: Top 8%
Surgical Sutures and Adhesives
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.