Evaluation of contrast-enhanced ultrasound-guided fine needle aspiration biopsy in thyroid nodule diagnosis: a study from two tertiary referral centers

Evaluation of contrast-enhanced ultrasound-guided fine needle aspiration biopsy in thyroid nodule diagnosis: a study from two tertiary referral centers PURPOSE This study aimed to compare the final definitive diagnosis (FDD) rate and accuracy of contrast-enhanced ultrasound (CEUS)-guided fine-needle aspiration biopsy (FNAB) with conventional US-guided FNAB. METHODSA two-center study was conducted to compare the diagnostic performance of FNAB with or without CEUS guiding between April 2014 and April 2024.In center 1, 1,074 patients with thyroid nodules who had undergone FNAB were retrospectively evaluated.Among them, 526 nodules were guided by CEUS, and 548 nodules were guided by conventional US.In center 2, 382 patients were included for a prospective study; 91 nodules received CEUS-guided FNAB and 291 nodules received conventional US-guided FNAB.The rate of non-diagnosis and indeterminate results of the two kinds of FNAB were calculated, and the FDD rate and diagnostic accuracy were compared in the two centers. RESULTSIn the retrospective study, there were significant differences between FNABs guided by CEUS and those guided by conventional US in the non-diagnostic rates (0.4% vs. 6.2%,P < 0.001) and indeterminate rates (4.4% vs. 11.1%,P < 0.001); the rates of FDD were 93.3% vs. 77.9%,(P < 0.001), and the accuracy was 99.8% vs. 98.1 (P = 0.015).In the prospective study, the non-diagnostic rates were 8.8% vs. 11.0% in the two groups (P = 0.695), and the indeterminate rates were 1.1% vs. 9.6% (P < 0.001); the rate of FDD was 80.2% vs. 69.7%,(P = 0.018), and the accuracy was 100% vs. 94.4,(P = 0.039). CONCLUSION CEUS-guided FNAB appears to have additional benefits in FDD and accuracy compared with conventional US-guided FNAB. CLINICAL SIGNIFICANCE CEUS-guided FNAB can reduce repeat FNABs and diagnostic surgeries.

Authors

Institutions

Publication Details

Journal
Diagnostic and Interventional Radiology
Published
2026-09-16
DOI
https://doi.org/10.4274/dir.2026.264246
Primary Topic
Thyroid Cancer Diagnosis and Treatment
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
article

Evaluation of contrast-enhanced ultrasound-guided fine needle aspiration biopsy in thyroid nodule diagnosis: a study from two tertiary referral centers

Zhan Jia, Ke-Xin Lou, Rong Wu, Yi-Feng Zhang et al.
Diagnostic and Interventional Radiology
Thyroid Cancer Diagnosis and Treatment
article

Evaluation of contrast-enhanced ultrasound-guided fine needle aspiration biopsy in thyroid nodule diagnosis: a study from two tertiary referral centers

Zhan Jia, Ke-Xin Lou, Rong Wu, Yi-Feng Zhang, Ji Ma, Long Liu
article en

Abstract

Evaluation of contrast-enhanced ultrasound-guided fine needle aspiration biopsy in thyroid nodule diagnosis: a study from two tertiary referral centers PURPOSE This study aimed to compare the final definitive diagnosis (FDD) rate and accuracy of contrast-enhanced ultrasound (CEUS)-guided fine-needle aspiration biopsy (FNAB) with conventional US-guided FNAB. METHODSA two-center study was conducted to compare the diagnostic performance of FNAB with or without CEUS guiding between April 2014 and April 2024.In center 1, 1,074 patients with thyroid nodules who had undergone FNAB were retrospectively evaluated.Among them, 526 nodules were guided by CEUS, and 548 nodules were guided by conventional US.In center 2, 382 patients were included for a prospective study; 91 nodules received CEUS-guided FNAB and 291 nodules received conventional US-guided FNAB.The rate of non-diagnosis and indeterminate results of the two kinds of FNAB were calculated, and the FDD rate and diagnostic accuracy were compared in the two centers. RESULTSIn the retrospective study, there were significant differences between FNABs guided by CEUS and those guided by conventional US in the non-diagnostic rates (0.4% vs. 6.2%,P < 0.001) and indeterminate rates (4.4% vs. 11.1%,P < 0.001); the rates of FDD were 93.3% vs. 77.9%,(P < 0.001), and the accuracy was 99.8% vs. 98.1 (P = 0.015).In the prospective study, the non-diagnostic rates were 8.8% vs. 11.0% in the two groups (P = 0.695), and the indeterminate rates were 1.1% vs. 9.6% (P < 0.001); the rate of FDD was 80.2% vs. 69.7%,(P = 0.018), and the accuracy was 100% vs. 94.4,(P = 0.039). CONCLUSION CEUS-guided FNAB appears to have additional benefits in FDD and accuracy compared with conventional US-guided FNAB. CLINICAL SIGNIFICANCE CEUS-guided FNAB can reduce repeat FNABs and diagnostic surgeries.

Diagnostic and Interventional Radiology
Jiangsu Normal University (CN), Jiading District Central Hospital (CN), Tongren Hospital (CN), Xuzhou Central Hospital (CN)
Zero hunger
Openalex Percentile: Top 12%
Thyroid Cancer Diagnosis and Treatment
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.