Generalisation of a deep learning-based exophthalmometry system using facial photographs for non-thyroidal orbital disease

AIMS: To evaluate agreement between photo-based automated exophthalmometry and manual Hertel exophthalmometry in healthy individuals and patients with non-thyroidal orbital disease, with a deep learning system trained exclusively in thyroid eye disease (TED) cohorts applied without retraining or fine-tuning. METHODS: This was a retrospective observational study. A total of 269 individuals were included in the study, including 95 healthy controls and 174 patients with unilateral non-TED orbital pathology. Automated measurements obtained using Glandy EXO from same-day frontal facial photographs were compared with corresponding manual Hertel exophthalmometry measurements. Agreement was assessed using Pearson correlation coefficient (PCC), mean absolute error (MAE), intraclass correlation coefficient (ICC) and Bland-Altman analysis. Diagnostic performance for clinically significant intereye asymmetry (>2.0 mm) was also evaluated. RESULTS: The system showed good agreement with Hertel exophthalmometry in the eyes of healthy controls (PCC 0.80; MAE 0.86 mm; ICC 0.80) as well as the affected (PCC 0.81; MAE 1.41 mm; ICC 0.75) and fellow (PCC 0.76; MAE 1.03 mm; ICC 0.75) eyes of patients. Overall, 84.8% of measurements were within 2.0 mm of the manual Hertel values. The sensitivity, specificity and accuracy of the system for detecting clinically significant intereye asymmetry were 59.6%, 95.0% and 83.3%, respectively. CONCLUSIONS: The TED-trained photoexophthalmometry system showed good agreement with Hertel measurements in healthy individuals and patients with non-TED orbital disease. These findings support its use as an adjunct to clinical examination for objective quantification and documentation of globe position.

Authors

Institutions

Publication Details

Journal
British Journal of Ophthalmology
Published
2026-09-15
DOI
https://doi.org/10.1136/bjo-2026-330182
Primary Topic
Ophthalmology and Eye Disorders
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
article

Generalisation of a deep learning-based exophthalmometry system using facial photographs for non-thyroidal orbital disease

Hyeong Ju Byeon, JaeSang Ko, Jae Hoon Moon, Jin Sook Yoon et al.
British Journal of Ophthalmology
Ophthalmology and Eye Disorders
article

Generalisation of a deep learning-based exophthalmometry system using facial photographs for non-thyroidal orbital disease

Hyeong Ju Byeon, JaeSang Ko, Jae Hoon Moon, Jin Sook Yoon, Joon Hyeon Park, Kyubo Shin, Jaemin Park, Jongchan Kim, HyunJo Jang
article en

Abstract

AIMS: To evaluate agreement between photo-based automated exophthalmometry and manual Hertel exophthalmometry in healthy individuals and patients with non-thyroidal orbital disease, with a deep learning system trained exclusively in thyroid eye disease (TED) cohorts applied without retraining or fine-tuning. METHODS: This was a retrospective observational study. A total of 269 individuals were included in the study, including 95 healthy controls and 174 patients with unilateral non-TED orbital pathology. Automated measurements obtained using Glandy EXO from same-day frontal facial photographs were compared with corresponding manual Hertel exophthalmometry measurements. Agreement was assessed using Pearson correlation coefficient (PCC), mean absolute error (MAE), intraclass correlation coefficient (ICC) and Bland-Altman analysis. Diagnostic performance for clinically significant intereye asymmetry (>2.0 mm) was also evaluated. RESULTS: The system showed good agreement with Hertel exophthalmometry in the eyes of healthy controls (PCC 0.80; MAE 0.86 mm; ICC 0.80) as well as the affected (PCC 0.81; MAE 1.41 mm; ICC 0.75) and fellow (PCC 0.76; MAE 1.03 mm; ICC 0.75) eyes of patients. Overall, 84.8% of measurements were within 2.0 mm of the manual Hertel values. The sensitivity, specificity and accuracy of the system for detecting clinically significant intereye asymmetry were 59.6%, 95.0% and 83.3%, respectively. CONCLUSIONS: The TED-trained photoexophthalmometry system showed good agreement with Hertel measurements in healthy individuals and patients with non-TED orbital disease. These findings support its use as an adjunct to clinical examination for objective quantification and documentation of globe position.

British Journal of Ophthalmology
Yonsei University (KR), Severance Hospital (KR), Seoul National University Bundang Hospital (KR), Gangnam Severance Hospital (KR)
Quality Education
Openalex Percentile: Top 12%
Ophthalmology and Eye Disorders
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.