Effect of access‐opening closure materials on fluid‐related mass gain and volumetric change in three‐dimensionally printed closed‐hollow obturator specimens

PURPOSE: To investigate how denture base resin and access-opening closure material affect fluid-related mass gain and micro-computed tomography-derived volumetric changes in three-dimensionally printed closed-hollow obturator specimens. MATERIALS AND METHODS: Specimens were printed from NextDent Denture 3D+ or Apex Base resin. Access-opening specimens had two 3-mm openings sealed with self-cure acrylic, material-matched printed resin (3D), PermaFlo Pink (PF), or CHAIRSIDE composite (ZC) (8 subgroups, n = 10; 80 specimens), plus 2 nonaccess-opening controls. After 24 h of conditioning, specimens underwent thermocycling (5°C-55°C; 2500-10,000 cycles) with gravimetric and micro-computed tomography measurements at baseline and after cycling. Net fluid-related mass gain (dW), relative fluid-related mass gain (rW), net micro-computed tomography-derived volumetric change (dV), and relative micro-computed tomography-derived volumetric change (rV) were analyzed. RESULTS: The thermocycling interval and closure material affected all outcomes, whereas the parent resin affected only dW. Gravimetric change was lowest with ZC and highest with self-cure acrylic; dV was lowest with 3D and highest with PF. Both outcome families were moderately correlated at all intervals (r = 0.39-0.56). dV/rV reached approximately 22%, 53%, and 80% of the 10,000-cycle values after 2500, 5000, and 7500 cycles, respectively. The controls exhibited the highest dW/rW and rV; net dV was highest in the PF access-opening groups. CONCLUSION: ZC minimized gravimetric change, whereas 3D minimized volumetric change. The preferred closure material depended on the prioritized outcome. Eliminating the access-opening interface did not prevent mass gain or cavity air-volume replacement.

Authors

Institutions

Publication Details

Journal
Journal of Prosthodontics
Published
2026-09-15
DOI
https://doi.org/10.1111/jopr.70239
Primary Topic
Dental materials and restorations
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
article

Effect of access‐opening closure materials on fluid‐related mass gain and volumetric change in three‐dimensionally printed closed‐hollow obturator specimens

Soranun Chantarangsu, Murali Srinivasan, Cheewin Towithelertkul, Visaluk Punyawattananon et al.
Journal of Prosthodontics
Dental materials and restorations
article

Effect of access‐opening closure materials on fluid‐related mass gain and volumetric change in three‐dimensionally printed closed‐hollow obturator specimens

Soranun Chantarangsu, Murali Srinivasan, Cheewin Towithelertkul, Visaluk Punyawattananon, Dusit Nantanapiboon, Wisarut Prawatvatchara, Raiwint Khunwisetkul
article en

Abstract

PURPOSE: To investigate how denture base resin and access-opening closure material affect fluid-related mass gain and micro-computed tomography-derived volumetric changes in three-dimensionally printed closed-hollow obturator specimens. MATERIALS AND METHODS: Specimens were printed from NextDent Denture 3D+ or Apex Base resin. Access-opening specimens had two 3-mm openings sealed with self-cure acrylic, material-matched printed resin (3D), PermaFlo Pink (PF), or CHAIRSIDE composite (ZC) (8 subgroups, n = 10; 80 specimens), plus 2 nonaccess-opening controls. After 24 h of conditioning, specimens underwent thermocycling (5°C-55°C; 2500-10,000 cycles) with gravimetric and micro-computed tomography measurements at baseline and after cycling. Net fluid-related mass gain (dW), relative fluid-related mass gain (rW), net micro-computed tomography-derived volumetric change (dV), and relative micro-computed tomography-derived volumetric change (rV) were analyzed. RESULTS: The thermocycling interval and closure material affected all outcomes, whereas the parent resin affected only dW. Gravimetric change was lowest with ZC and highest with self-cure acrylic; dV was lowest with 3D and highest with PF. Both outcome families were moderately correlated at all intervals (r = 0.39-0.56). dV/rV reached approximately 22%, 53%, and 80% of the 10,000-cycle values after 2500, 5000, and 7500 cycles, respectively. The controls exhibited the highest dW/rW and rV; net dV was highest in the PF access-opening groups. CONCLUSION: ZC minimized gravimetric change, whereas 3D minimized volumetric change. The preferred closure material depended on the prioritized outcome. Eliminating the access-opening interface did not prevent mass gain or cavity air-volume replacement.

Journal of Prosthodontics
Chulalongkorn University (TH), University of Zurich (CH), Mahidol University (TH), King Mongkut's Institute of Technology Ladkrabang (TH)
Sustainable cities and communities
Openalex Percentile: Top 9%
Dental materials and restorations
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.