Plasma Endothelin-1 as an Independent Predictor of Mortality in Vietnamese Hemodialysis Patients: A Prospective Cohort Study

Background: Endothelin-1 (ET-1) is a potent vasoconstrictor implicated in multiple complications of end-stage renal disease. This study evaluated the predictive value of baseline plasma ET-1 for 18-month all-cause mortality in Vietnamese hemodialysis patients. Methods: A prospective cohort study enrolled 222 patients on maintenance hemodialysis. Plasma ET-1 concentrations were quantified using an enzyme-linked immunosorbent assay (ELISA). The primary endpoint was 18-month all-cause mortality. Predictive accuracy was evaluated using receiver operating characteristic (ROC) curves, Kaplan–Meier survival analysis, and Cox proportional hazards regression models. Results: During the 18-month follow-up, 57 patients (25.68%) died. Non-survivors exhibited significantly higher median ET-1 levels compared to survivors (131.08 vs. 46.69 pg/mL, p < 0.001). The optimal ET-1 cutoff for predicting mortality was 85.06 pg/mL (area under the curve [AUC] = 0.875). Kaplan–Meier analysis demonstrated significantly worse survival in patients with ET-1 > 85.06 pg/mL (log-rank p < 0.001). In a multivariable Cox regression model adjusted for age, apparent treatment-resistant hypertension (aTRH), diabetes mellitus, and heart failure using a forward stepwise selection method, log2-transformed ET-1 remained a significant and independent predictor of all-cause mortality (hazard ratio [HR], 2.06; 95% confidence interval [CI], 1.52–2.79; p < 0.001). Conclusions: Baseline plasma ET-1 was independently associated with 18-month all-cause mortality in this single-center cohort of Vietnamese patients receiving maintenance hemodialysis. External validation is required before ET-1 can be recommended for routine clinical risk stratification.

Authors

Institutions

Publication Details

Journal
Kidney and Dialysis
Published
2026-09-15
DOI
https://doi.org/10.3390/kidneydial6030061
Primary Topic
Nitric Oxide and Endothelin Effects
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
article

Plasma Endothelin-1 as an Independent Predictor of Mortality in Vietnamese Hemodialysis Patients: A Prospective Cohort Study

Linh Thi Thao Nguyen, Tan Huynh Ngoc, Tam Vo, Dat Hoang Phan
Kidney and Dialysis
Nitric Oxide and Endothelin Effects
article

Plasma Endothelin-1 as an Independent Predictor of Mortality in Vietnamese Hemodialysis Patients: A Prospective Cohort Study

Linh Thi Thao Nguyen, Tan Huynh Ngoc, Tam Vo, Dat Hoang Phan
article en

Abstract

Background: Endothelin-1 (ET-1) is a potent vasoconstrictor implicated in multiple complications of end-stage renal disease. This study evaluated the predictive value of baseline plasma ET-1 for 18-month all-cause mortality in Vietnamese hemodialysis patients. Methods: A prospective cohort study enrolled 222 patients on maintenance hemodialysis. Plasma ET-1 concentrations were quantified using an enzyme-linked immunosorbent assay (ELISA). The primary endpoint was 18-month all-cause mortality. Predictive accuracy was evaluated using receiver operating characteristic (ROC) curves, Kaplan–Meier survival analysis, and Cox proportional hazards regression models. Results: During the 18-month follow-up, 57 patients (25.68%) died. Non-survivors exhibited significantly higher median ET-1 levels compared to survivors (131.08 vs. 46.69 pg/mL, p < 0.001). The optimal ET-1 cutoff for predicting mortality was 85.06 pg/mL (area under the curve [AUC] = 0.875). Kaplan–Meier analysis demonstrated significantly worse survival in patients with ET-1 > 85.06 pg/mL (log-rank p < 0.001). In a multivariable Cox regression model adjusted for age, apparent treatment-resistant hypertension (aTRH), diabetes mellitus, and heart failure using a forward stepwise selection method, log2-transformed ET-1 remained a significant and independent predictor of all-cause mortality (hazard ratio [HR], 2.06; 95% confidence interval [CI], 1.52–2.79; p < 0.001). Conclusions: Baseline plasma ET-1 was independently associated with 18-month all-cause mortality in this single-center cohort of Vietnamese patients receiving maintenance hemodialysis. External validation is required before ET-1 can be recommended for routine clinical risk stratification.

Kidney and DialysisVol. 6(3)
Can Tho University (VN), Hue University (VN)
Good health and well-being
Openalex Percentile: Top 11%
Nitric Oxide and Endothelin Effects
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Plasma Endothelin-1 as an Independent Predictor of Mortality in Vietnamese Hemodialysis Patients: A Prospective Cohort Study — Linh Thi Thao Nguyen, Tan Huynh Ngoc, et al. · Kidney and Dialysis (2026) | TGRS Research Map | TGRS