Accuracy and clinical passive fit of reverse and standard scan body protocols for complete‐arch implant‐supported digital impressions: An in vitro study

PURPOSE: The purpose of this in vitro study was to compare the reverse scan body (RSB) and standard scan body (SCB) protocols for complete-arch implant-supported digital impressions with respect to root mean square (RMS), linear deviation, and angular deviation values, as well as clinical passive fit. MATERIALS AND METHODS: Configurations with four and six implants were created on edentulous maxillary and mandibular casts. Digital impressions were obtained with an intraoral scanner using the standard and RSB protocols (10 scans per subgroup; 80 datasets total) and superimposed onto reference datasets acquired with a laboratory scanner. RMS, linear, and angular deviation values were calculated. Clinical passive fit of cobalt-chromium verification jigs fabricated from digital data was evaluated by visual inspection, screw-resistance test, and radiographic assessment. RESULTS: Total RMS values did not differ significantly between the standard and RSB protocols (0.0384 ± 0.0017 vs. 0.0395 ± 0.0012 mm; p = 0.530), although the scan protocol × jaw interaction was significant (p = 0.001). In four-implant casts, the RSB protocol demonstrated significantly lower linear deviation than the SCB protocol (0.0618 vs. 0.0951 mm; p < 0.001); in six-implant casts, no main effect of protocol was found, although several interactions were significant. Angular deviation findings were configuration-dependent. Clinical passive fit was acceptable in 95% of verification jigs fabricated with the RSB protocol and 90% of verification jigs fabricated with the SCB protocol. CONCLUSIONS: Within the limitations of this in vitro study, the RSB protocol demonstrated accuracy comparable to the SCB protocol, with more stable implant position transfer in four-implant configurations and a high clinical passive fit rate, supporting its use as a reliable alternative in complete-arch digital implant workflows.

Authors

Institutions

Publication Details

Journal
Journal of Prosthodontics
Published
2026-09-15
DOI
https://doi.org/10.1111/jopr.70241
Primary Topic
Dental Implant Techniques and Outcomes
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
article

Accuracy and clinical passive fit of reverse and standard scan body protocols for complete‐arch implant‐supported digital impressions: An in vitro study

İkbal Leblebicioğlu Kurtuluş, Rabia Kilicaslan Dasdelen, Kerem Kilic
Journal of Prosthodontics
Dental Implant Techniques and Outcomes
article

Accuracy and clinical passive fit of reverse and standard scan body protocols for complete‐arch implant‐supported digital impressions: An in vitro study

İkbal Leblebicioğlu Kurtuluş, Rabia Kilicaslan Dasdelen, Kerem Kilic
article en

Abstract

PURPOSE: The purpose of this in vitro study was to compare the reverse scan body (RSB) and standard scan body (SCB) protocols for complete-arch implant-supported digital impressions with respect to root mean square (RMS), linear deviation, and angular deviation values, as well as clinical passive fit. MATERIALS AND METHODS: Configurations with four and six implants were created on edentulous maxillary and mandibular casts. Digital impressions were obtained with an intraoral scanner using the standard and RSB protocols (10 scans per subgroup; 80 datasets total) and superimposed onto reference datasets acquired with a laboratory scanner. RMS, linear, and angular deviation values were calculated. Clinical passive fit of cobalt-chromium verification jigs fabricated from digital data was evaluated by visual inspection, screw-resistance test, and radiographic assessment. RESULTS: Total RMS values did not differ significantly between the standard and RSB protocols (0.0384 ± 0.0017 vs. 0.0395 ± 0.0012 mm; p = 0.530), although the scan protocol × jaw interaction was significant (p = 0.001). In four-implant casts, the RSB protocol demonstrated significantly lower linear deviation than the SCB protocol (0.0618 vs. 0.0951 mm; p < 0.001); in six-implant casts, no main effect of protocol was found, although several interactions were significant. Angular deviation findings were configuration-dependent. Clinical passive fit was acceptable in 95% of verification jigs fabricated with the RSB protocol and 90% of verification jigs fabricated with the SCB protocol. CONCLUSIONS: Within the limitations of this in vitro study, the RSB protocol demonstrated accuracy comparable to the SCB protocol, with more stable implant position transfer in four-implant configurations and a high clinical passive fit rate, supporting its use as a reliable alternative in complete-arch digital implant workflows.

Journal of Prosthodontics
Erciyes University (TR)
Bilimsel Araştırma Projeleri, Erciyes Üniversitesi
Openalex Percentile: Top 9%
Dental Implant Techniques and Outcomes
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.