Cardiac pacemakers in dogs: programming parameters

Objective: To report the behavior of the main parameters used in the evaluation of cardiac pacemakers (PMs) in dogs, associated complications, and survival times. Methods: This retrospective cohort study evaluated dogs that received PMs (from 2016 through 2023) at a veterinary teaching hospital. Dogs of various breeds, ages, and sexes with at least 1 baseline assessment were included. The PM parameters pacing threshold amplitude, impedance (or conductance), and estimated battery life were assessed immediately after PM insertion and at reevaluation times (≤ 7, ≤ 90, ≤ 547, ≤ 912, and ≥ 912 days). Complications and survival rates were also evaluated. Results: The median survival time of 11 dogs was 30 months. Two complications were recorded: seroma and suture dehiscence. A reduction in impedance over time was further validated by a significant Skillings-Mack test (χ2 = 12.692; P = .0054). Pacing threshold amplitude and estimated battery life did not significantly change. Conclusions: PM implantation in dogs is safe and eliminates clinical signs. A reduction in myocardial impedance (or increased conductance) is expected, but impedance assessment should consider individual baselines, observing the behavior rather than just the normal range or isolated values. Baseline pacing threshold amplitude also varies between individuals and tends to decrease over time. No significant reduction in estimated battery life was observed during the study period, probably due to high device longevity. Clinical Relevance: This study provides the first data for PM parameters in dogs. The results suggest that clinical interpretation should focus on longitudinal parameter behavior relative to baseline values rather than solely on the reference range.

Authors

Institutions

Publication Details

Journal
American Journal of Veterinary Research
Published
2026-09-15
DOI
https://doi.org/10.2460/ajvr.26.03.0102
Primary Topic
Cardiac pacing and defibrillation studies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
article

Cardiac pacemakers in dogs: programming parameters

Marlos Gonçalves Sousa, Peterson Triches Dornbusch, Mônica Kanashiro Oyafuso, Caio Hamamura et al.
American Journal of Veterinary Research
Cardiac pacing and defibrillation studies
article

Cardiac pacemakers in dogs: programming parameters

Marlos Gonçalves Sousa, Peterson Triches Dornbusch, Mônica Kanashiro Oyafuso, Caio Hamamura, Juan Carlos Duque Moreno
article en

Abstract

Objective: To report the behavior of the main parameters used in the evaluation of cardiac pacemakers (PMs) in dogs, associated complications, and survival times. Methods: This retrospective cohort study evaluated dogs that received PMs (from 2016 through 2023) at a veterinary teaching hospital. Dogs of various breeds, ages, and sexes with at least 1 baseline assessment were included. The PM parameters pacing threshold amplitude, impedance (or conductance), and estimated battery life were assessed immediately after PM insertion and at reevaluation times (≤ 7, ≤ 90, ≤ 547, ≤ 912, and ≥ 912 days). Complications and survival rates were also evaluated. Results: The median survival time of 11 dogs was 30 months. Two complications were recorded: seroma and suture dehiscence. A reduction in impedance over time was further validated by a significant Skillings-Mack test (χ2 = 12.692; P = .0054). Pacing threshold amplitude and estimated battery life did not significantly change. Conclusions: PM implantation in dogs is safe and eliminates clinical signs. A reduction in myocardial impedance (or increased conductance) is expected, but impedance assessment should consider individual baselines, observing the behavior rather than just the normal range or isolated values. Baseline pacing threshold amplitude also varies between individuals and tends to decrease over time. No significant reduction in estimated battery life was observed during the study period, probably due to high device longevity. Clinical Relevance: This study provides the first data for PM parameters in dogs. The results suggest that clinical interpretation should focus on longitudinal parameter behavior relative to baseline values rather than solely on the reference range.

American Journal of Veterinary Research
Federal Institute of São Paulo (BR), Serviço Autônomo de Água e Esgoto de Jaboticabal (BR), Núcleo de Pesquisas Aplicadas (Brazil) (BR), Universidade Federal do Paraná (BR), Universidade Estadual Paulista (Unesp) (BR)
Good health and well-being
Openalex Percentile: Top 11%
Cardiac pacing and defibrillation studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.