Evaluation of Locked Plates Versus 3-Dimensional Plates for Fixation of Mandibular Angle Fractures: A Clinical and Radiologic Study

INTRODUCTION: Mandibular fractures are among the most prevalent forms of facial trauma, with the angle region being particularly susceptible to them as a result of its anatomic fragility and exposure to masticatory forces. The purpose of this study was to evaluate the efficacy and postoperative complications of 2.00 mm unicortical fixed plates and 3-dimensional plates in the surgical correction of displaced mandibular angle fractures. METHODS: This is a prospective, randomized clinical study included 20 patients of both sexes, divided randomly into 2 groups according to the technique of fixation. Group I: patients were treated using a non-compression monocortical 2 mm 3D miniplate and group II: patients were treated using a non-compression monocortical 2 mm locked miniplate. RESULTS: Postoperative radiography was taken for each patient on the 2nd, 3rd, and 6th months. The status was assessed using a score from 1 to 3. Score I showed poorly reduced fractures that had required a second operation to correct poor alignment and unacceptable occlusion. Score II showed reduced fractures that were slightly displaced but had a satisfactory occlusion. Score III showed radiologic evidence of precise anatomic reduction at the fracture site. All patients had shown radiographic score I preoperatively, whereas all patients at 1 week, 3 months, and 6 months had shown radiographic score 3, revealing properly reduced fracture bony segments and a properly aligned inferior border without step deformity at different appointments. CONCLUSIONS: Both the 3D miniplate and secured plate systems were used to successfully stabilize the fracture fragments after the mandibular angle fractures fixation.

Authors

Institutions

Publication Details

Journal
Journal of Craniofacial Surgery
Published
2026-09-15
DOI
https://doi.org/10.1097/scs.0000000000013400
Primary Topic
Facial Trauma and Fracture Management
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
article

Evaluation of Locked Plates Versus 3-Dimensional Plates for Fixation of Mandibular Angle Fractures: A Clinical and Radiologic Study

Abdelaziz Abdullah, Ashraf Abdelfattah Mahmoud, Mohamed Ashraf Mahmoud, Mohamed Ahmed Elsaaty
Journal of Craniofacial Surgery
Facial Trauma and Fracture Management
article

Evaluation of Locked Plates Versus 3-Dimensional Plates for Fixation of Mandibular Angle Fractures: A Clinical and Radiologic Study

Abdelaziz Abdullah, Ashraf Abdelfattah Mahmoud, Mohamed Ashraf Mahmoud, Mohamed Ahmed Elsaaty
article en

Abstract

INTRODUCTION: Mandibular fractures are among the most prevalent forms of facial trauma, with the angle region being particularly susceptible to them as a result of its anatomic fragility and exposure to masticatory forces. The purpose of this study was to evaluate the efficacy and postoperative complications of 2.00 mm unicortical fixed plates and 3-dimensional plates in the surgical correction of displaced mandibular angle fractures. METHODS: This is a prospective, randomized clinical study included 20 patients of both sexes, divided randomly into 2 groups according to the technique of fixation. Group I: patients were treated using a non-compression monocortical 2 mm 3D miniplate and group II: patients were treated using a non-compression monocortical 2 mm locked miniplate. RESULTS: Postoperative radiography was taken for each patient on the 2nd, 3rd, and 6th months. The status was assessed using a score from 1 to 3. Score I showed poorly reduced fractures that had required a second operation to correct poor alignment and unacceptable occlusion. Score II showed reduced fractures that were slightly displaced but had a satisfactory occlusion. Score III showed radiologic evidence of precise anatomic reduction at the fracture site. All patients had shown radiographic score I preoperatively, whereas all patients at 1 week, 3 months, and 6 months had shown radiographic score 3, revealing properly reduced fracture bony segments and a properly aligned inferior border without step deformity at different appointments. CONCLUSIONS: Both the 3D miniplate and secured plate systems were used to successfully stabilize the fracture fragments after the mandibular angle fractures fixation.

Journal of Craniofacial Surgery
Al-Azhar University (EG)
Openalex Percentile: Top 9%
Facial Trauma and Fracture Management
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Evaluation of Locked Plates Versus 3-Dimensional Plates for Fixation of Mandibular Angle Fractures: A Clinical and Radiologic Study — Abdelaziz Abdullah, Ashraf Abdelfattah Mahmoud, et al. · Journal of Craniofacial Surgery (2026) | TGRS Research Map | TGRS