SqueakSpeed: An Accurate, Open-Source Raspberry Pi System for Real-Time Circadian Analysis of Voluntary Wheel Running

In mice, voluntary wheel running (VWR) is a stress-free, naturalistic model for studying exercise behavior in rodents, yet commercial cyclometers used to quantify running parameters have not been validated at physiological rodent speeds. Our objective was to develop SqueakSpeed, an open-source Raspberry Pi-based system and compare its accuracy and linearity to commercial cyclometers. We hypothesize that SqueakSpeed will replicate the commercial cyclometer’s recorded running parameters while providing superior circadian resolution. SqueakSpeed uses a hall sensor and neodymium magnets to record speed, distance, and acceleration, transmitting data to a cloud server in real time. VWR was recorded in CD-1 mice (~8–10 weeks old) over six days with both SqueakSpeed and a VDO M2.1 cyclometer. Discrepant distance measurements prompted mechanical validation using a DC motor across physiological running speeds (0.02–0.20 m/s). Surprisingly, the cyclometer showed overestimation at lower speeds with poor accuracy and linearity (RMSE = 0.061, MAE = 0.046, R 2 = 0.48) and a mean bias of -0.038, wide 95% limits of agreement (-0.136 to 0.060 m/s), significant speed-dependent proportional bias (slope=1.235, p=0.0003). In contrast, SqueakSpeed demonstrated high accuracy and , R 2 = 0.99), minimal mean bias (-0.00034 m/s), and narrower limits of agreement (-0.0039 to 0.0032 m/s). Commercial cyclometers are inaccurate and non-linear within the physiological range of rodent running speeds. SqueakSpeed provides accurate, real-time quantification of wheel running with high-resolution circadian analysis. These findings support its use as a precise and versatile tool for behavioral studies

Authors

Institutions

Publication Details

Journal
American Journal of Physiology-Heart and Circulatory Physiology
Published
2026-09-14
DOI
https://doi.org/10.1152/ajpheart.00386.2026
Primary Topic
Genetics and Physical Performance
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
article

SqueakSpeed: An Accurate, Open-Source Raspberry Pi System for Real-Time Circadian Analysis of Voluntary Wheel Running

Jeremy A. Simpson, Keith R. Brunt, Patrick Sanosa, Amelia R. Malicki et al.
American Journal of Physiology-Heart and Circulatory Physiology
Genetics and Physical Performance
article

SqueakSpeed: An Accurate, Open-Source Raspberry Pi System for Real-Time Circadian Analysis of Voluntary Wheel Running

Jeremy A. Simpson, Keith R. Brunt, Patrick Sanosa, Amelia R. Malicki, Ngoc K. Le, JP Marrow
article en

Abstract

In mice, voluntary wheel running (VWR) is a stress-free, naturalistic model for studying exercise behavior in rodents, yet commercial cyclometers used to quantify running parameters have not been validated at physiological rodent speeds. Our objective was to develop SqueakSpeed, an open-source Raspberry Pi-based system and compare its accuracy and linearity to commercial cyclometers. We hypothesize that SqueakSpeed will replicate the commercial cyclometer’s recorded running parameters while providing superior circadian resolution. SqueakSpeed uses a hall sensor and neodymium magnets to record speed, distance, and acceleration, transmitting data to a cloud server in real time. VWR was recorded in CD-1 mice (~8–10 weeks old) over six days with both SqueakSpeed and a VDO M2.1 cyclometer. Discrepant distance measurements prompted mechanical validation using a DC motor across physiological running speeds (0.02–0.20 m/s). Surprisingly, the cyclometer showed overestimation at lower speeds with poor accuracy and linearity (RMSE = 0.061, MAE = 0.046, R 2 = 0.48) and a mean bias of -0.038, wide 95% limits of agreement (-0.136 to 0.060 m/s), significant speed-dependent proportional bias (slope=1.235, p=0.0003). In contrast, SqueakSpeed demonstrated high accuracy and , R 2 = 0.99), minimal mean bias (-0.00034 m/s), and narrower limits of agreement (-0.0039 to 0.0032 m/s). Commercial cyclometers are inaccurate and non-linear within the physiological range of rodent running speeds. SqueakSpeed provides accurate, real-time quantification of wheel running with high-resolution circadian analysis. These findings support its use as a precise and versatile tool for behavioral studies

American Journal of Physiology-Heart and Circulatory Physiology
Dalhousie University (CA), Impact (CA), University of Guelph (CA)
Openalex Percentile: Top 11%
Genetics and Physical Performance
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.