The Removal of legacy 226Ra and 137Cs Medical Sources from Paraguay to the United States Under the International Atomic Energy Agency’s Global 226Ra Management Initiative

OBJECTIVE: To describe the transfer of six decommissioned legacy 226Ra sources totaling 9.92 ± 2.0% GBq (268 mCi), and 116 decommissioned 137Cs sources totaling 41.1 ± 2.0% GBq (1,110 mCi), from the Republic of Paraguay to the United States, within the framework of the International Atomic Energy Agency's Global Radium-226 Management Initiative. METHODS: The sources were removed from their original shielded packaging, a cement-filled 200-L steel drum. The sources were identified via spectroscopic analysis, assayed, and repackaged in six Type A containers; five containers contained 226Ra sources, and one contained all the 137Cs sources. The containers were wipe-tested, and dose rates on contact and at 1.0 m were measured. RESULTS: External wipe tests on the containers revealed counts slightly above natural background in one of the units (14% above background), well below the allowable surface contamination for a II-Yellow-coded (medium risk) Type A container. Dose rates at 1.0 m for all containers (i.e., their transport indices) ranged between 1.1 μSv h-1 ± 10% (0.11 mrem h-1) and 4.4 μSv h-1 ± 10% (0.44 mrem h-1), also corresponding to a II-Yellow code. Thus all containers were II-Yellow-coded for air shipment to the United States. The transfer of the containers from hospital to airport, inspection, weighing at customs, and loading onto the aircraft proceeded without incident. CONCLUSIONS: The safe transfer of decommissioned 226Ra and 137Cs medical sources from possessor to receptor countries is possible provided all national and international safety guidelines are adhered to. Based on our experience, we recommend that any country considering such a transfer avail itself of the safety and security standards associated with the International Atomic Energy Agency's Global Radium-226 Management Initiative.

Authors

Institutions

Publication Details

Journal
Health Physics
Published
2026-09-14
DOI
https://doi.org/10.1097/hp.0000000000002211
Primary Topic
Radioactivity and Radon Measurements
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
article

The Removal of legacy 226Ra and 137Cs Medical Sources from Paraguay to the United States Under the International Atomic Energy Agency’s Global 226Ra Management Initiative

Eduardo Galiano
Health Physics
Radioactivity and Radon Measurements
article

The Removal of legacy 226Ra and 137Cs Medical Sources from Paraguay to the United States Under the International Atomic Energy Agency’s Global 226Ra Management Initiative

Eduardo Galiano
article en

Abstract

OBJECTIVE: To describe the transfer of six decommissioned legacy 226Ra sources totaling 9.92 ± 2.0% GBq (268 mCi), and 116 decommissioned 137Cs sources totaling 41.1 ± 2.0% GBq (1,110 mCi), from the Republic of Paraguay to the United States, within the framework of the International Atomic Energy Agency's Global Radium-226 Management Initiative. METHODS: The sources were removed from their original shielded packaging, a cement-filled 200-L steel drum. The sources were identified via spectroscopic analysis, assayed, and repackaged in six Type A containers; five containers contained 226Ra sources, and one contained all the 137Cs sources. The containers were wipe-tested, and dose rates on contact and at 1.0 m were measured. RESULTS: External wipe tests on the containers revealed counts slightly above natural background in one of the units (14% above background), well below the allowable surface contamination for a II-Yellow-coded (medium risk) Type A container. Dose rates at 1.0 m for all containers (i.e., their transport indices) ranged between 1.1 μSv h-1 ± 10% (0.11 mrem h-1) and 4.4 μSv h-1 ± 10% (0.44 mrem h-1), also corresponding to a II-Yellow code. Thus all containers were II-Yellow-coded for air shipment to the United States. The transfer of the containers from hospital to airport, inspection, weighing at customs, and loading onto the aircraft proceeded without incident. CONCLUSIONS: The safe transfer of decommissioned 226Ra and 137Cs medical sources from possessor to receptor countries is possible provided all national and international safety guidelines are adhered to. Based on our experience, we recommend that any country considering such a transfer avail itself of the safety and security standards associated with the International Atomic Energy Agency's Global Radium-226 Management Initiative.

Health Physics
Santander Port Authority (ES)
Affordable and clean energy
Openalex Percentile: Top 10%
Radioactivity and Radon Measurements
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines