Peri-Implant Tissue Health and Prosthodontic Outcomes of a Cylindrical-Conical Implant with a Progressive Thread Design at Five-Year Follow-Up: A Single-Center Cross-Sectional Retrospective Study

Objectives: We aim to assess the 5-year clinical outcomes of a cylindrical-conical implant system with a progressive thread design and a sandblasted, acid-etched surface and its fixed prostheses under routine clinical conditions. Methods: This retrospective single-center cross-sectional follow-up study included patients treated with implants with a progressive thread design and an internal butt-joint connection between January 2019 and August 2020 at a specialist referral practice in Germany. Of 112 patients treated, 44 (94 implants with fixed restorations) attended the five-year recall. Outcomes were the Functional Implant Prosthodontic Score (FIPS), peri-implant tissue health parameters (bleeding on probing, suppuration, dehiscence, width of keratinized mucosa, and other signs of inflammation), marginal bone level on periapical radiographs, and implant survival. Results: All 94 implants available for examination remained in situ at five years, corresponding to 100% survival among recalled implants. Mean FIPS was 7.6 out of 10 (interproximal 1.3, occlusion 1.8, design 1.6, mucosa 1.4, bone 1.5). Bleeding on probing was absent in 37.2% of implants and present at ≥3 of 6 sites in 30.9%; suppuration was absent in all cases. Bleeding was descriptively more frequent where keratinized mucosa was narrow: implants with <2 mm bled at nearly three times as many sites as those with ≥2 mm. No implant showed a marginal bone level ≥2.0 mm apical to the shoulder. Conclusions: Within the limitations of this retrospective cross-sectional follow-up study, the implant system with a progressive thread design demonstrated favorable 5-year prosthodontic, biological and radiological findings under referral-practice conditions.

Authors

Institutions

Publication Details

Journal
Dentistry Journal
Published
2026-09-14
DOI
https://doi.org/10.3390/dj14090594
Primary Topic
Dental Implant Techniques and Outcomes
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
article

Peri-Implant Tissue Health and Prosthodontic Outcomes of a Cylindrical-Conical Implant with a Progressive Thread Design at Five-Year Follow-Up: A Single-Center Cross-Sectional Retrospective Study

Tobias Graf, Jörg-Martin Ruppin
Dentistry Journal
Dental Implant Techniques and Outcomes
article

Peri-Implant Tissue Health and Prosthodontic Outcomes of a Cylindrical-Conical Implant with a Progressive Thread Design at Five-Year Follow-Up: A Single-Center Cross-Sectional Retrospective Study

Tobias Graf, Jörg-Martin Ruppin
article en

Abstract

Objectives: We aim to assess the 5-year clinical outcomes of a cylindrical-conical implant system with a progressive thread design and a sandblasted, acid-etched surface and its fixed prostheses under routine clinical conditions. Methods: This retrospective single-center cross-sectional follow-up study included patients treated with implants with a progressive thread design and an internal butt-joint connection between January 2019 and August 2020 at a specialist referral practice in Germany. Of 112 patients treated, 44 (94 implants with fixed restorations) attended the five-year recall. Outcomes were the Functional Implant Prosthodontic Score (FIPS), peri-implant tissue health parameters (bleeding on probing, suppuration, dehiscence, width of keratinized mucosa, and other signs of inflammation), marginal bone level on periapical radiographs, and implant survival. Results: All 94 implants available for examination remained in situ at five years, corresponding to 100% survival among recalled implants. Mean FIPS was 7.6 out of 10 (interproximal 1.3, occlusion 1.8, design 1.6, mucosa 1.4, bone 1.5). Bleeding on probing was absent in 37.2% of implants and present at ≥3 of 6 sites in 30.9%; suppuration was absent in all cases. Bleeding was descriptively more frequent where keratinized mucosa was narrow: implants with <2 mm bled at nearly three times as many sites as those with ≥2 mm. No implant showed a marginal bone level ≥2.0 mm apical to the shoulder. Conclusions: Within the limitations of this retrospective cross-sectional follow-up study, the implant system with a progressive thread design demonstrated favorable 5-year prosthodontic, biological and radiological findings under referral-practice conditions.

Dentistry JournalVol. 14(9)
LMU Klinikum (DE), K-Implant (Germany) (DE), Ludwig-Maximilians-Universität München (DE)
Openalex Percentile: Top 8%
Dental Implant Techniques and Outcomes
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.