Zero-Water Thermal Architecture for High-Density Artificial Intelligence Data Centers

Abstract The rapid growth of artificial intelligence has produced a corresponding increase in computational power density and, consequently, thermal power density within modern data centers. Conventional air cooling becomes increasingly difficult as accelerator-level heat dissipation reaches hundreds of watts to kilowatts per device, while many high-density facilities increasingly employ liquid-assisted cooling and water-intensive heat-rejection systems. Although liquid cooling can provide excellent thermal performance, water consumption presents a significant sustainability challenge, particularly in regions experiencing water stress. This paper proposes a Zero-Water AI Data Center (ZW-AIDC) architecture in which heat generated by high-density AI accelerators is transported through a sealed, non-water, two-phase thermal network and rejected to the atmosphere through dry air-cooled condensers. The proposed architecture eliminates evaporative cooling towers, chilled-water distribution loops, and direct water consumption for heat rejection. At the device level, vapor chambers and high-conductivity thermal interfaces spread localized heat. At the rack level, a sealed two-phase working-fluid loop transports thermal energy away from the electronics. At the facility boundary, dry finned condensers reject heat directly to ambient air. A thermodynamic and heat-transfer framework is developed for estimating device heat flux, two-phase heat-transfer requirements, condenser area, working-fluid mass flow, fan power, compressor requirements, and overall cooling coefficient of performance. The architecture is further evaluated for hypothetical 1 MW, 10 MW, and 100 MW IT loads. The analysis shows that zero-water operation is physically feasible, but eliminating water does not eliminate the thermal-management cost: the principal penalties are increased dry-condenser area, increased airflow requirements, sensitivity to ambient temperature, and potentially higher parasitic electrical consumption. The proposed architecture therefore represents a trade between water independence and thermal-infrastructure efficiency. The paper establishes a framework for future experimental validation and optimization of zero-water cooling systems for high-density AI computing.

Authors

Institutions

Publication Details

Journal
Zenodo (CERN European Organization for Nuclear Research)
Published
2026-09-12
DOI
https://doi.org/10.5281/zenodo.22727321
Primary Topic
Heat Transfer and Optimization
Type
preprint
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
preprint

Zero-Water Thermal Architecture for High-Density Artificial Intelligence Data Centers

Nazat Md. Shaikhul Hadis
Zenodo (CERN European Organization for Nuclear Research)
Heat Transfer and Optimization
preprint

Zero-Water Thermal Architecture for High-Density Artificial Intelligence Data Centers

Nazat Md. Shaikhul Hadis
preprint en

Abstract

Abstract The rapid growth of artificial intelligence has produced a corresponding increase in computational power density and, consequently, thermal power density within modern data centers. Conventional air cooling becomes increasingly difficult as accelerator-level heat dissipation reaches hundreds of watts to kilowatts per device, while many high-density facilities increasingly employ liquid-assisted cooling and water-intensive heat-rejection systems. Although liquid cooling can provide excellent thermal performance, water consumption presents a significant sustainability challenge, particularly in regions experiencing water stress. This paper proposes a Zero-Water AI Data Center (ZW-AIDC) architecture in which heat generated by high-density AI accelerators is transported through a sealed, non-water, two-phase thermal network and rejected to the atmosphere through dry air-cooled condensers. The proposed architecture eliminates evaporative cooling towers, chilled-water distribution loops, and direct water consumption for heat rejection. At the device level, vapor chambers and high-conductivity thermal interfaces spread localized heat. At the rack level, a sealed two-phase working-fluid loop transports thermal energy away from the electronics. At the facility boundary, dry finned condensers reject heat directly to ambient air. A thermodynamic and heat-transfer framework is developed for estimating device heat flux, two-phase heat-transfer requirements, condenser area, working-fluid mass flow, fan power, compressor requirements, and overall cooling coefficient of performance. The architecture is further evaluated for hypothetical 1 MW, 10 MW, and 100 MW IT loads. The analysis shows that zero-water operation is physically feasible, but eliminating water does not eliminate the thermal-management cost: the principal penalties are increased dry-condenser area, increased airflow requirements, sensitivity to ambient temperature, and potentially higher parasitic electrical consumption. The proposed architecture therefore represents a trade between water independence and thermal-infrastructure efficiency. The paper establishes a framework for future experimental validation and optimization of zero-water cooling systems for high-density AI computing.

Zenodo (CERN European Organization for Nuclear Research)
University of Science and Technology (YE)
Industry, innovation and infrastructure
Heat Transfer and Optimization
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.